Fan control (IT8622 Super-I/O, LPC)

The chassis fan is not on the front board. It hangs off the mainboard's IT8622 Super-I/O over LPC, a separate chip and bus from the LCD and the MSP430. See hardware.md for where this sits relative to the rest of the front-panel hardware.

Why it needs a module

TrueNAS SCALE does not load it87 by default, and the chip cannot be autoprobed. The driver has to poke LPC I/O ports directly to find it. Without the module, there is no fan*_input anywhere under /sys/class/hwmon, which is also why rn426_panel.py's temp page shows Fan ?: page_temp() globs every hwmon node for fan*_input and simply finds none.

Loading it

modprobe it87 force_id=0x8622

Try plain modprobe it87 first. force_id=0x8622 is what's confirmed working on this RN426. Do not cargo-cult it onto other hardware. Forcing the wrong ID makes the driver talk to a chip that isn't actually there, which gets you garbage reads/writes instead of a clean probe failure.

Verified result once loaded: an it8622 hwmon node appears, exposing:

Node Observed Notes
fan2_input ~860 RPM at idle chassis fan
fan3_input 0 unpopulated header, always reads 0
pwm2 / pwm2_enable PWM duty + mode control for the chassis fan

Once fan2_input exists, rn426_panel.py picks it up automatically, page_temp() already globs every hwmon for fan*_input.

⚠️ Do not trust the chip's built-in automatic mode

On this chip, temp1 and temp3 read a permanent -128C (disconnected sensors). The IT8622's own automatic fan mode chases whichever temp zone pwm2 is bound to, if that's one of the dead -128C inputs, the fan pulses/hunts as the chip's control logic reacts to garbage. That's why tools/it87-fancontrol.sh ignores auto mode and drives pwm2 in manual mode (pwm2_enable=1) from a userspace curve based on real drive/CPU temps instead.

⚠️ PWM floor

pwm2 values below ~12 stall the fan outright. 12 is the real floor (~858 RPM), the fan-control script never commands lower than that.

The fan-curve script

tools/it87-fancontrol.sh is the working controller pulled off this NAS. Summary of what it does (see the script for the exact tunables):

  • Polls every 10 s.
  • Takes the hottest drivetemp sensor across all disks, EMA-smoothed to avoid chasing single-sample noise, and maps it through a curve: floor below 48C, full speed by 60C.
  • Takes CPU package temp (coretemp) as a backstop: floor below 58C, full by 78C.
  • Commands pwm2 to whichever of the two curves wants more speed.
  • Slew-limits the PWM change per tick, up to +10/tick (~4 min floor to full) and down to -4/tick (~10 min full to floor), so the fan ramps smoothly instead of jumping.
  • Logs to $LOG (default /var/log/it87-fancontrol.log, overridable via the LOG env var) whenever the commanded PWM moves by 4 or more. Writes are infrequent but unbounded over time. If long-term log size matters, add a logrotate entry for $LOG or point LOG at a tmpfs path.

⚠️ pwm2 holds its last value if this script dies. There is no hardware fallback. See above. That means the script must run under something that restarts it, which is exactly what the systemd-run --property=Restart=always install recipe below is for; do not run it as a bare backgrounded process. As of this revision the script also installs a trap ... EXIT INT TERM that forces pwm2 to 255 on any exit, so a crash makes the fan loud, not silent-and-hot, even in the gap before Restart=always brings it back.

Persistence

Do not use /etc/modules, /etc/modules-load.d, or a plain systemd unit for the modprobe. Like everything else on the root filesystem, changes there don't survive a SCALE update (SCALE updates into a new boot environment, so anything not registered in the config DB is gone). Register the module load in the TrueNAS config DB instead:

System Settings -> Advanced -> Init/Shutdown Scripts -> add an entry:

  • Type: Command
  • Command: modprobe it87 force_id=0x8622
  • When: PREINIT

PREINIT is just tidier, the timing isn't critical. page_temp() re-globs hwmon every ~5 s and the fan script polls for the it8622 node for up to 60 s, so a POSTINIT modprobe would also work.

Installing the fan-curve script itself

Install tools/it87-fancontrol.sh as a POSTINIT init script the same way install.sh registers the panel daemon, via systemd-run, so it survives reboots without needing a unit file on the root filesystem (changes there don't survive a SCALE update):

cp tools/it87-fancontrol.sh /mnt/<your-pool>/rn426-panel/it87-fancontrol.sh
chmod +x /mnt/<your-pool>/rn426-panel/it87-fancontrol.sh
systemd-run --unit=it87-fancontrol --property=Restart=always \
  --property=RestartSec=10 /bin/bash /mnt/<your-pool>/rn426-panel/it87-fancontrol.sh

Then add a second System Settings -> Advanced -> Init/Shutdown Scripts entry (Type: Command, When: POSTINIT) with that same systemd-run command so it re-registers on every boot, after the PREINIT modprobe it87 above has already run.