In the context of developing microscopy schemas in the in-depth metadata curation workflow, we suggest the following additions to specimenprep / device:
Optical Implementation Device Usage and Optical Implementation Device :
Extends /specimenPrep/schemas/activity/devicePlacement.schema.tpl.json
| Field |
Description |
Required |
Type |
placementCoordinates |
Stereotaxic coordinates relative to a reference |
Yes |
sands/CoordinatePoint |
device |
Add all the ophys devices placed during this activity. |
Yes |
linked -> Optical Implementation Device |
depth |
Final depth of distal optical element from pial surface |
Yes |
QuantitativeValue |
insertionAngleDeg |
Angle of insertion relative to skull normal or AP axis |
Optional |
QuantitativeValue |
windowGlassThickness |
Coverslip thickness |
Optional |
QuantitativeValue |
postOpRecoveryDays |
Days between surgery and first imaging |
Optional |
QuantitativeValue |
complications |
Intra-/post-op complications |
Optional |
string |
opticalAlignmentCheck |
Method/result verifying alignment |
Optional |
string |
motionStabilityScore |
Stability of implant over time |
Optional |
string |
In the context of developing microscopy schemas in the in-depth metadata curation workflow, we suggest the following additions to specimenprep / device:
Optical Implementation Device UsageandOptical Implementation Device:Extends
/specimenPrep/schemas/activity/devicePlacement.schema.tpl.jsonplacementCoordinatessands/CoordinatePointdeviceOptical Implementation DevicedepthQuantitativeValueinsertionAngleDegQuantitativeValuewindowGlassThicknessQuantitativeValuepostOpRecoveryDaysQuantitativeValuecomplicationsopticalAlignmentCheckmotionStabilityScore