Diagnose: Hardware Failure Diagnosis

Systematic procedures for diagnosing Dell PowerEdge hardware failures. Work through the relevant symptom section top-to-bottom. Do not skip steps.

iDRAC10 (17G): Hardware diagnostic commands (racadm lclog, hwinventory, getsysinfo) work the same on iDRAC10. LCD error codes may include new codes for 17G-specific components — check Dell's 17G documentation for codes not listed here.


Symptom: Server Won't Power On

Decision Tree

  1. Check the AC power source
    • If the wall outlet or PDU port is dead --> test with a known-good device, check breaker
    • If AC is confirmed good --> continue
  2. Check PSU LEDs on the back of the chassis
    • If no LEDs are lit on any PSU --> suspect AC wiring or PDU issue, try a different power cable
    • If one PSU LED is green and another is off --> suspect failed PSU, reseat or replace the dark PSU
    • If PSU LEDs are blinking amber --> PSU fault detected, check racadm hwinventory PSU once iDRAC is reachable
    • If PSU LEDs are solid green --> power input is good, continue
  3. Press the power button on the front panel
    • If nothing happens --> check that the power button is not disabled in iDRAC (racadm get System.Power.PowerButtonMode)
    • If the system begins POST --> monitor for errors during POST
  4. Check iDRAC power log (if iDRAC is reachable on standby power)
    racadm lclog view -s last -c 20 | grep -i power
    • If log shows "Power supply lost AC input" --> confirm PDU/cable
    • If log shows "Power usage exceeded threshold" --> check power cap settings: racadm get System.Power
  5. If none of the above resolve it --> suspect motherboard failure, open Dell support case

Symptom: Amber Blinking on Chassis

Decision Tree

  1. Decode the LED blink pattern
    • Solid amber = system detected a fault but is operational
    • Blinking amber = system detected a critical fault
    • Blinking amber/green alternating = system is identifying (someone ran a locate command)
  2. Check the LCD panel on the front of the chassis (if equipped)
    • Record the exact message code (e.g., "E1000", "W1228")
    • Cross-reference with the LCD Status Messages table below
  3. Query iDRAC for system health
    racadm getsysinfo | grep -A5 "System Information"
  4. Pull recent events
    racadm lclog view -s last -c 50
  5. Check IPMI sensor data repository for any sensors in critical state
    ipmitool sdr list | grep -E "cr|nr"
    • "cr" = critical threshold exceeded
    • "nr" = non-recoverable
  6. If the amber LED appeared after a hardware change --> reseat the changed component (DIMM, drive, PCIe card)
  7. If no recent changes --> match the fault in the SEL to the correct sub-section below

Symptom: Memory Errors

Decision Tree

  1. Identify the failing DIMM slot
    racadm hwinventory Memory | grep -B2 -A10 "Error"
  2. Check ECC error counts
    ipmitool sel list | grep -i memory
    • Correctable ECC errors (CE) below 10 in 24 hours --> monitor, no immediate action
    • Correctable ECC errors (CE) above 100 in 24 hours --> schedule DIMM replacement
    • Uncorrectable ECC error (UE) --> DIMM has failed, replace immediately
  3. Identify the exact DIMM location
    racadm hwinventory Memory | grep -E "DIMM\.(Slot|Status|Size|Speed|Manufacturer|PartNum|SerialNum)"
  4. Check if the DIMM has been disabled by the BIOS
    racadm get BIOS.MemSettings
    • If MemOpMode is "OptimizerMode" and a DIMM is missing from inventory --> BIOS may have disabled a failing DIMM
  5. Run embedded diagnostics if the server can be taken offline
    racadm diagnostics run -m memory
  6. If replacing a DIMM --> match the exact part number and speed, follow Dell population rules for the platform (check the hardware owner's manual for the specific PowerEdge model)

WARNING: Replacing DIMMs requires powering off the server. Schedule a maintenance window.


Symptom: CPU Thermal Throttling

Decision Tree

  1. Check current CPU temperatures
    ipmitool sdr list | grep -i temp
    • Inlet temperature above 35C --> check datacenter cooling, check for hot aisle containment breach
    • CPU temperature above 85C --> throttling is likely active
  2. Check fan status
    ipmitool sdr list | grep -i fan
    racadm getfanreqinfo
    • If any fan shows 0 RPM --> fan has failed, replace fan module
    • If all fans are running but at maximum RPM --> airflow obstruction or failed thermal paste
  3. Check for airflow obstructions
    • Verify all blanks are installed in empty drive bays and PCIe slots
    • Verify cable routing is not blocking airflow
    • Verify the air shroud / air baffle is properly seated
  4. Check power/thermal profile
    racadm get BIOS.SysProfileSettings.SysProfile
    • If set to "PerfOptimized" --> consider switching to "PerfPerWattOptimizedDapc" for better thermal management
  5. If temperatures remain critical with good airflow and working fans --> suspect thermal paste degradation or heatsink issue, open Dell support case

Symptom: Fan Failures

Decision Tree

  1. Identify the failed fan
    racadm getfanreqinfo
    ipmitool sdr list | grep -i fan
  2. Check if the failure is a single fan or multiple
    • Single fan failure --> replace the fan module (hot-swappable on most PowerEdge models)
    • Multiple simultaneous fan failures --> suspect backplane or motherboard fan controller issue
  3. Reseat the fan module before replacing
    • Power off is NOT required for hot-swap fan modules on 14G and newer
    • After reseating, wait 30 seconds and recheck: ipmitool sdr list | grep -i fan
  4. If the fan is replaced and still shows failure --> check the fan connector on the system board, open Dell support case

WARNING: Operating without sufficient fans will cause thermal throttling and may trigger automatic shutdown. Replace failed fans immediately.


Symptom: PSU Degraded

Decision Tree

  1. Check PSU inventory and status
    racadm hwinventory PSU
  2. Check redundancy status
    racadm get System.Power.Redundancy
    • "Full" = both PSUs operational
    • "Lost" = one PSU has failed, server running on single PSU
  3. Check the PSU LED on the back of the chassis
    • Green = normal
    • Blinking amber = PSU fault
    • Off = no AC input or PSU failure
  4. If PSU shows degraded but LED is green --> check PSU firmware, attempt racadm racreset to clear stale status
  5. If PSU has genuinely failed
    • Confirm the server can run on the remaining PSU (check power draw vs single PSU capacity)
    • Order replacement PSU matching the exact wattage rating
    • PSU is hot-swappable on all rack-mount PowerEdge servers

WARNING: If redundancy is lost, a failure of the remaining PSU will cause an unplanned outage. Expedite replacement.


Dell LCD Status Messages (Common Codes)

Code Severity Message Meaning Action
E1000 Critical Failsafe voltage error Voltage regulator failure Power off immediately, open support case
E1114 Critical Ambient Temp exceeds allowed range Inlet temperature too high Check datacenter cooling
E1116 Critical Memory disabled, temp above allowed range DIMM overheated Check fans, check airflow
E1210 Critical Motherboard battery failure CMOS battery dead Replace CMOS battery at next maintenance window
E1211 Warning RAID controller battery failure RAID BBU/capacitor failed Replace RAID battery/capacitor
E122E Critical On-board configuration error Config mismatch Reseat components, clear NVRAM if needed
E1310 Critical Fan missing Fan module removed or unseated Reseat or replace fan module
E1410 Critical System Fatal Error detected CPU machine check exception Check SEL for details, may need board replacement
E1614 Critical Power supply lost AC input AC feed interrupted Check PDU, check power cable
E2010 Critical Memory not detected No DIMMs found Reseat DIMMs, check population rules
E2012 Warning Memory configuration error DIMM population rule violated Consult owner's manual for correct DIMM placement
W1228 Warning RAID controller degraded Virtual disk degraded Check storage skill for drive replacement
I1910 Info CPU thermal trip CPU hit thermal limit Check fans, check airflow, check ambient temp
I1912 Info SEL full System event log is full Clear SEL: racadm lclog clear

System Event Log Analysis

Pull the log

racadm lclog view -s last -c 100

Patterns to look for

Pattern Indicates Action
Repeated "correctable memory error" on same DIMM DIMM degrading Schedule replacement
"Uncorrectable memory error" DIMM failure Replace immediately
"Predictive failure" on physical disk Drive SMART threshold exceeded Replace drive proactively
"Power supply lost AC input" followed by "Power supply AC input restored" AC power flapping Check PDU, check cable seating
"Temperature threshold exceeded" repeated Cooling issue Check fans, check datacenter HVAC
"RAID controller battery charge below threshold" BBU degrading Replace at next maintenance
"PCI parity error" PCIe card or slot failure Reseat card, test in different slot
"OS watchdog timer expired" OS hang / kernel panic Check OS logs, not a hardware issue unless recurring
"Lifecycle Controller not ready" LC in recovery state See known-issues for workaround

Export the full log for Dell support

racadm lclog export -f /tmp/lclog_export.xml
racadm techsupreport collect -t SysInfo,TTYLog

When to Open a Dell Support Case

Open a case if:

  • Any "E1xxx" critical LCD code that is not resolved by reseating components
  • Uncorrectable memory errors
  • Multiple simultaneous component failures
  • RAID controller not detected
  • POST does not complete
  • Motherboard or CPU replacement is needed

Information to gather before calling

# Service Tag (7-character alphanumeric)
racadm getsysinfo | grep "Service Tag"

# Express Service Code (numeric, derived from service tag)
racadm getsysinfo | grep "Express Svc Code"

# iDRAC firmware version
racadm getversion

# Full system event log
racadm lclog export -f /tmp/lclog.xml

# Hardware inventory
racadm hwinventory export -f /tmp/hwinventory.xml

# Tech support report (comprehensive)
racadm techsupreport collect -t SysInfo,TTYLog,OSAppAll

Dell ProSupport phone: 1-800-456-3355 (US). Have the service tag ready.