diff --git a/bricksrc/entity_properties.csv b/bricksrc/entity_properties.csv new file mode 100644 index 00000000..9982ccff --- /dev/null +++ b/bricksrc/entity_properties.csv @@ -0,0 +1,52 @@ +@id,brick:placeholder1,brick:placeholder2,brick:placeholder3,brick:hasQuantity/Enumeration,brick:placeholder4,rdfs:subPropertyOf,todo:,skos:definition +brick:aggregate,,,,,,,aggregate,Description of how the data for this point is aggregated +brick:area,,,,quantitykind:Area,,,,Entity has 2-dimensional area +brick:azimuth,,,,quantitykind:Azimuth,,,,(Horizontal) angle between a projected vector and a reference vector (typically a compass bearing). The projected vector usually indicates the direction of a face or plane. +brick:buildingPrimaryFunction,,,,,,,(deprecated),Enumerated string applied to a site record to indicate the building's primary function. The list of primary functions is derived from the US Energy Star program (adopted from Project Haystack) +brick:buildingThermalTransmittance,,,,quantitykind:ThermalTransmittance,,brick:thermalTransmittance,building,The area-weighted average heat transfer coefficient (commonly referred to as a U-value) for a building envelope +brick:conversionEfficiency,,,,quantitykind:Efficiency,,,conversion,The percent efficiency of the conversion process (usually to power or energy) carried out by the entity +brick:coolingCapacity,,,,,,,cooling capacity,Measurement of a chiller ability to remove heat (adopted from Project Haystack) +brick:coordinates,,,,,,,coordinates,The location of an entity in latitude/longitude +brick:currentFlowType,,,,quantitykind:ElectricCurrent,,,flow type,The current flow type of the entity +brick:deprecation,,,,,,,deprecation,Marks a concept as deprecated +brick:electricalComplexPower,,,,quantitykind:ElectricPower,,,,Associated electrical complexity with the entity +brick:electricalFlow,,,,,,,electrical flow,Entity has this electrical flow relative to the building' +brick:electricalPhaseCount,,,,quantitykind:NumberOfElectricalPhases,,,,Entity has these phases +brick:electricalPhases,,,,,,,electrical phases,Entity has these electrical AC phases +brick:electricVehicleChargerDirectionality,,,,,,,electric vehicle charger directionality,Indicates if the EVSE charger supports bidirectional charging or just unidirectional charging of the EV battery +brick:electricVehicleChargerType,,,,,,,electric vehicle charger type,"Which type of EVSE charger this is, e.g. Level 1 (up to up to 2.5kW of AC power on 1 phase 120V input), Level 2 (direct AC power but can use higher voltage and up to 3 phases), or Level 3 (direct DC power)" +brick:electricVehicleConnectorType,,,,,,,electric vehicle connector type,Identifies which kind of connector the port has. This property helps identify the physical connection required between the vehicle and the charging equipment. +brick:grossArea,,,brick:Gross,quantitykind:Area,,brick:area,,Entity has gross 2-dimensional area +brick:isVirtualMeter,,,,,,,is virtual meter,"True if the associated meter is 'virtual', i.e. a logical meter which includes or aggregates information from a variety of sources such as other submeters or equipment." +brick:lastKnownValue,,,,,,,last known value,The last known value of the Point entity +brick:measuredModuleConversionEfficiency,brick:Measured,,,quantitykind:Efficiency,,brick:conversionEfficiency,module conversion,The measured percentage of sunlight that is converted into usable power +brick:measuredPowerInput,brick:Measured,,,quantitykind:ElectricPower,brick:Input,,,The nominal measured power input of the entity +brick:measuredPowerOutput,brick:Measured,,,quantitykind:ElectricPower,brick:Output,,,The nominal measured power output of the entity +brick:netArea,,,brick:Net,quantitykind:Area,,brick:area,,Entity has net 2-dimensional area +brick:operationalStage,,,,,,,operational stage,The associated operational stage +brick:operationalStageCount,,,,quantitykind:Count,,,operational stage,The number of operational stages supported by this equipment +brick:panelArea,,,,quantitykind:Area,,brick:area,panel,"Surface area of a panel, such as a PV panel" +brick:ratedApparentPower,brick:Rated,,,quantitykind:ApparentPower,,,,The nominal rated apparent power of the entity +brick:ratedCorrelatedColorTemperature,brick:Rated,,,quantitykind:CorrelatedColorTemperature,,,,The nominal rated correlated color temperature of the entity +brick:ratedCurrentInput,brick:Rated,,,quantitykind:ElectricCurrent,brick:Input,,,The nominal rated current input of the entity +brick:ratedCurrentOutput,brick:Rated,,,quantitykind:ElectricCurrent,brick:Output,,,The nominal rated current output of the entity +brick:ratedLuminousFlux,brick:Rated,,,quantitykind:LuminousFlux,,,,The nominal rated luminous flux of the entity +brick:ratedMaximumCurrentInput,brick:Rated,brick:Maximum,,quantitykind:ElectricCurrent,brick:Input,brick:ratedCurrentInput,,The maximum current that can be input to the entity +brick:ratedMaximumCurrentOutput,brick:Rated,brick:Maximum,,quantitykind:ElectricCurrent,brick:Output,brick:ratedCurrentOutput,,The maximum current that can be output by the entity +brick:ratedMaximumVoltageInput,brick:Rated,brick:Maximum,,quantitykind:Voltage,brick:Input,brick:ratedVoltageInput,,The maximum voltage that can be input to the entity +brick:ratedMaximumVoltageOutput,brick:Rated,brick:Maximum,,quantitykind:Voltage,brick:Output,brick:ratedVoltageOutput,,The maximum voltage that can be output by the entity +brick:ratedMinimumCurrentInput,brick:Rated,brick:Minimum,,quantitykind:ElectricCurrent,brick:Input,brick:ratedCurrentInput,,The minimum current that can be input to the entity +brick:ratedMinimumCurrentOutput,brick:Rated,brick:Minimum,,quantitykind:ElectricCurrent,brick:Output,brick:ratedCurrentOutput,,The minimum current that can be output by the entity +brick:ratedMinimumVoltageInput,brick:Rated,brick:Minimum,,quantitykind:Voltage,brick:Input,brick:ratedVoltageInput,,The minimum voltage that can be input to the entity +brick:ratedMinimumVoltageOutput,brick:Rated,brick:Minimum,,quantitykind:Voltage,brick:Output,brick:ratedVoltageOutput,,The minimum voltage that can be output by the entity +brick:ratedModuleConversionEfficiency,brick:Rated,,,quantitykind:Efficiency,,brick:conversionEfficiency,module conversion,"The *rated* percentage of sunlight that is converted into usable power, as measured using Standard Test Conditions (STC): 1000 W/sqm irradiance, 25 degC panel temperature, no wind" +brick:ratedPowerInput,brick:Rated,,,quantitykind:ElectricPower,brick:Input,,,The nominal rated power input of the entity +brick:ratedPowerOutput,brick:Rated,,,quantitykind:ElectricPower,brick:Output,,,The nominal rated power output of the entity +brick:ratedVoltageInput,brick:Rated,,,quantitykind:Voltage,brick:Input,,,The nominal rated voltage input of the entity +brick:ratedVoltageOutput,brick:Rated,,,quantitykind:Voltage,brick:Output,,,The nominal rated voltage output of the entity +brick:resolution,,,,,,,resolution,The resolution of the entity specifing the smallest measurable or controllable increment +brick:temperatureCoefficientofPmax,,,,quantitykind:Temperature,,,coefficientof pmax,The % change in power output for every degree celsius that the entity is hotter than 25 degrees celsius +brick:thermalTransmittance,,,,quantitykind:ThermalTransmittance,,,,The area-weighted average heat transfer coefficient (commonly referred to as a U-value) +brick:tilt,,,,quantitykind:Tilt,,,,The direction an entity is facing in degrees above the horizon +brick:volume,,,,quantitykind:Volume,,,,Entity has 3-dimensional volume +brick:yearBuilt,,,,,,,year built,Four digit year that a building was first built. (adopted from Project Haystack) diff --git a/bricksrc/point_events.csv b/bricksrc/point_events.csv new file mode 100644 index 00000000..9201bba3 --- /dev/null +++ b/bricksrc/point_events.csv @@ -0,0 +1,46 @@ +@id,qudt:hasQuantityKind,rdfs:subClassOf,todo:,rdfs:comment +rec:AbsoluteHumidityObservation,quantitykind:AbsoluteHumidity,rec:ObservationEvent,, +rec:AccelerationObservation,quantitykind:Acceleration,rec:ObservationEvent,, +rec:ActuationEvent,,rec:PointEvent,, +rec:AngleObservation,quantitykind:Angle,rec:ObservationEvent,, +rec:AngularAccelerationObservation,quantitykind:AngularAcceleration,rec:ObservationEvent,, +rec:AngularVelocityObservation,quantitykind:AngularVelocity,rec:ObservationEvent,, +rec:AreaObservation,quantitykind:Area,rec:ObservationEvent,, +rec:BooleanValueObservation,,rec:ObservationEvent,,Generic xsd:boolean value observation that is not specific to any particular QUDT quantitykind or unit. +rec:CapacitanceObservation,quantitykind:Capacitance,rec:ObservationEvent,, +rec:DataRateObservation,quantitykind:DataRate,rec:ObservationEvent,, +rec:DataSizeObservation,quantitykind:InformationEntropy,rec:ObservationEvent,, +rec:DensityObservation,quantitykind:Density,rec:ObservationEvent,, +rec:DistanceObservation,quantitykind:Distance,rec:ObservationEvent,, +rec:DoubleValueObservation,,rec:ObservationEvent,,Generic xsd:double value observation that is not specific to any particular QUDT quantitykind or unit. +rec:ElectricChargeObservation,quantitykind:ElectricCharge,rec:ObservationEvent,, +rec:ElectricCurrentObservation,quantitykind:ElectricCurrent,rec:ObservationEvent,, +rec:EnergyObservation,quantitykind:Energy,rec:ObservationEvent,, +rec:ExceptionEvent,,rec:PointEvent,, +rec:ForceObservation,quantitykind:Force,rec:ObservationEvent,, +rec:FrequencyObservation,quantitykind:Frequency,rec:ObservationEvent,, +rec:IlluminanceObservation,quantitykind:Illuminance,rec:ObservationEvent,, +rec:InductanceObservation,quantitykind:Inductance,rec:ObservationEvent,, +rec:IntegerValueObservation,,rec:ObservationEvent,,Generic xsd:int value observation that is not specific to any particular QUDT quantitykind or unit. +rec:LengthObservation,quantitykind:Length,rec:ObservationEvent,, +rec:LuminanceObservation,quantitykind:Luminance,rec:ObservationEvent,, +rec:LuminousFluxObservation,quantitykind:LuminousFlux,rec:ObservationEvent,, +rec:LuminousIntensityObservation,quantitykind:LuminousIntensity,rec:ObservationEvent,, +rec:MagneticFluxObservation,quantitykind:MagneticFlux,rec:ObservationEvent,, +rec:MassFlowRateObservation,quantitykind:MassFlowRate,rec:ObservationEvent,, +rec:MassObservation,quantitykind:Mass,rec:ObservationEvent,, +rec:ObservationEvent,,rec:PointEvent,, +rec:PointEvent,,rec:PointEvent,,"An event emanating from or targeting a Point; e.g., an individual Observation from a Sensor point, or an Actuation sent to a Command point. In other terms, the Points indicate the capability of some Space or Equipment to emit or accept data, while this class represents those actual data messages. Note that in most non-trivially sized systems, these events are not stored in the knowledge graph itself, but are rather forwarded to some C&C system or time series database." +rec:PowerObservation,quantitykind:Power,rec:ObservationEvent,, +rec:PressureObservation,quantitykind:Pressure,rec:ObservationEvent,, +rec:RelativeHumidityObservation,quantitykind:RelativeHumidity,rec:ObservationEvent,, +rec:ResistanceObservation,quantitykind:Resistance,rec:ObservationEvent,, +rec:SoundPressureObservation,quantitykind:SoundPressure,rec:ObservationEvent,, +rec:TemperatureObservation,quantitykind:Temperature,rec:ObservationEvent,, +rec:ThrustObservation,quantitykind:Thrust,rec:ObservationEvent,, +rec:TimeSpanObservation,quantitykind:Time,rec:ObservationEvent,, +rec:TorqueObservation,quantitykind:Torque,rec:ObservationEvent,, +rec:VelocityObservation,quantitykind:Velocity,rec:ObservationEvent,, +rec:VoltageObservation,quantitykind:Voltage,rec:ObservationEvent,, +rec:VolumeFlowRateObservation,quantitykind:VolumeFlowRate,rec:ObservationEvent,, +rec:VolumeObservation,quantitykind:Volume,rec:ObservationEvent,, diff --git a/bricksrc/points.csv b/bricksrc/points.csv new file mode 100644 index 00000000..0fd987e8 --- /dev/null +++ b/bricksrc/points.csv @@ -0,0 +1,869 @@ +@id,brick:inMode,brick:ofSystem/Equipment/Process,brick:hasSubstance,brick:ofConstituent,brick:isDifferential,brick:hasQuantity/Enumeration,rdfs:subClassOf,todo:,skos:definition +brick:Absolute_Humidity_Sensor,,,brick:Air,,,quantitykind:AbsoluteHumidity,brick:Sensor,,Measures the present state of absolute humidity +brick:Acceleration_Time_Setpoint,,brick:Acceleration,,,,quantitykind:Time,brick:Setpoint,, +brick:Active_Power_Sensor,,,,,,quantitykind:ActivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, results in net transfer of energy in one direction" +brick:Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of some value +brick:Air_Alarm,,,brick:Air,,,,brick:Alarm,, +brick:Air_Differential_Pressure_Sensor,,,brick:Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between two regions of air +brick:Air_Differential_Pressure_Setpoint,,,brick:Air,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a air duct or conduit +brick:Air_Enthalpy_Sensor,,,brick:Air,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of air +brick:Air_Flow_Alarm,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Alarm,,An alarm related to air flow. +brick:Air_Flow_Deadband_Setpoint,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of air flow +brick:Air_Flow_Demand_Setpoint,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of air flow required for a process +brick:Air_Flow_Loss_Alarm,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Loss_Alarm,,An alarm that indicates loss in air flow. +brick:Air_Flow_Sensor,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air +brick:Air_Flow_Setpoint,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets air flow +brick:Air_Flow_Setpoint_Limit,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Air_Grains_Sensor,,,brick:Air,,,quantitykind:SpecificHumidity,brick:Sensor,,Measures the mass of water vapor in air +brick:Air_Pressure_Sensor,,,brick:Air,,,quantitykind:Pressure,brick:Sensor,,Measures the pressure of the surrounding air. +brick:Air_Pressure_Setpoint,,,brick:Air,,,quantitykind:Pressure,brick:Setpoint,, +brick:Air_Quality_Sensor,,,,,,,brick:Air_Quality_Sensor,,A sensor which provides a measure of air quality +brick:Air_Static_Pressure_Sensor,,,brick:Air,,,quantitykind:StaticPressure,brick:Sensor,,"Measures the pressure exerted by the air in a system, not influenced by its motion." +brick:Air_Static_Pressure_Step_Parameter,,,brick:Air,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Air_Temperature_Alarm,,,brick:Air,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of air. +brick:Air_Temperature_Integral_Time_Parameter,,,brick:Air,,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Air_Temperature_Sensor,,,brick:Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of air +brick:Air_Temperature_Setpoint,,,brick:Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air +brick:Air_Temperature_Setpoint_Limit,,,brick:Air,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Air_Temperature_Setpoint. +brick:Air_Temperature_Step_Parameter,,,brick:Air,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Air_Velocity_Pressure_Sensor,,,brick:Air,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total air pressure and static air pressure. +brick:Air_Wet_Bulb_Temperature_Sensor,,,brick:Air,,,quantitykind:WetBulbTemperature,brick:Sensor,, +brick:Alarm,,,,,,,brick:Alarm,,Alarm points are signals (either audible or visual) that alert an operator to an off-normal condition which requires some form of corrective action +brick:Alarm_Delay_Parameter,,,,,,,brick:Alarm_Delay_Parameter,,A parameter determining how long to delay an alarm after sufficient conditions have been met +brick:Alarm_Sensitivity_Parameter,,,,,,,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate an alarm. +brick:Ammonia_Sensor,,,brick:Air,brick:Ammonia,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,, +brick:Angle_Sensor,,,,,,quantitykind:Angle,brick:Sensor,,Measues the planar angle of some phenomenon +brick:Apparent_Power_Sensor,,,,,,quantitykind:ApparentPower,brick:Sensor,,Measures apparent power in an AC electrical system +brick:Automatic_Mode_Command,,,,,,brick:EnumerationKind-Automatic_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Automatic"" mode" +brick:Availability_Status,,,,,,brick:EnumerationKind-Availability,brick:Status,,"Indicates if a piece of equipment, system, or functionality is available for operation" +brick:Average_Cooling_Demand_Sensor,,brick:Cooling,,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a cooling process as the amount of power consumed over some interval +brick:Average_Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Average_Sensor,(alias), +brick:Average_Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,,quantitykind:StaticPressure,brick:Average_Sensor,,The computed average static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Average_Heating_Demand_Sensor,,brick:Heating,,,,,brick:Average_Demand_Sensor,,Measures the average power consumed by a heating process as the amount of power consumed over some interval +brick:Average_Supply_Air_Flow_Sensor,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Average_Sensor,,The computed average flow of supply air over some interval +brick:Average_Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,,quantitykind:Temperature,brick:Average_Sensor,,"The computed average temperature of air in a zone, over some period of time" +brick:Battery_Voltage_Sensor,,brick:Battery,,,,quantitykind:Voltage,brick:Sensor,,Measures the capacity of a battery +brick:Boiler_Command,,brick:Boiler,,,,,brick:Command,,A command to control a boiler +brick:Box_Mode_Command,,,,,,,,(deprecated), +brick:Building_Air_Humidity_Setpoint,,,brick:Building_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Setpoint for humidity in a building +brick:Building_Air_Static_Pressure_Sensor,,,brick:Building_Air,,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within a building +brick:Building_Air_Static_Pressure_Setpoint,,,brick:Building_Air,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of the entire building +brick:Bypass_Air_Flow_Sensor,,,brick:Bypass_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass air +brick:Bypass_Air_Humidity_Setpoint,,,brick:Bypass_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for bypass air +brick:Bypass_Command,,,,,,,,(deprecated), +brick:Bypass_Water_Flow_Sensor,,,brick:Bypass_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of bypass water +brick:Bypass_Water_Flow_Setpoint,,,brick:Bypass_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of bypass water +brick:Capacity_Sensor,,,,,,quantitykind:Capacity,brick:Sensor,, +brick:Change_Filter_Alarm,,,,,,,brick:Change_Filter_Alarm,,An alarm that indicates that a filter must be changed +brick:Chilled_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of chilled water +brick:Chilled_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Reset_Status,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Setpoint,, +brick:Chilled_Water_Differential_Pressure_Load_Shed_Status,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Status,, +brick:Chilled_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Chilled_Water_Differential_Pressure_Sensor,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a chilled water valve +brick:Chilled_Water_Differential_Pressure_Setpoint,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry chilled water +brick:Chilled_Water_Differential_Pressure_Step_Parameter,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Chilled_Water_Differential_Temperature_Sensor,,,brick:Chilled_Water,,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the chiller or other water cooling device and leaving water from the same chiller or other water cooling device +brick:Chilled_Water_Flow_Sensor,,,brick:Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a chilled water circuit +brick:Chilled_Water_Flow_Setpoint,,,brick:Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled water +brick:Chilled_Water_Gauge_Pressure_Sensor,,,brick:Chilled_Water,,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of chilled water +brick:Chilled_Water_Static_Pressure_Setpoint,,,brick:Chilled_Water,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of chilled water +brick:Chilled_Water_System_Enable_Command,,brick:Chilled_Water_System,,,,,brick:Enable_Command,,Enables operation of the chilled water system +brick:Chilled_Water_Temperature_Sensor,,,brick:Chilled_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water +brick:Chilled_Water_Temperature_Setpoint,,,brick:Chilled_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of chilled water +brick:Close_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Close_Setpoint. +brick:CO_Differential_Sensor,,,brick:Air,brick:CO,brick:Differential,quantitykind:AmountOfSubstanceFraction,brick:Sensor,, +brick:CO_Level_Sensor,,,brick:Air,brick:CO,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO +brick:CO_Sensor,,,brick:Air,brick:CO,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures properties of CO +brick:CO2_Alarm,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the presence of carbon dioxide. +brick:CO2_Alarm_Sensitivity_Parameter,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a CO2 alarm. +brick:CO2_Differential_Sensor,,,brick:Air,brick:CO2,brick:Differential,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the difference between CO2 levels of inside and outside air +brick:CO2_Level_Sensor,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO2 in air +brick:CO2_Sensor,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures properties of CO2 in air +brick:CO2_Setpoint,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Setpoint,,Sets some property of CO2 +brick:Coldest_Zone_Air_Temperature_Sensor,,,,,,,,(deprecated),The zone temperature that is coldest; drives the supply temperature of hot air. A computed value rather than a physical sensor. Also referred to as a 'Lowest Zone Air Temperature Sensor' +brick:Collection_Basin_Water_Level_Alarm,,,brick:Collection_Basin_Water,,,quantitykind:LiquidLevel,brick:Alarm,,"An alarm that indicates a high or low level of water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Level_Sensor,,,brick:Collection_Basin_Water,,,quantitykind:LiquidLevel,brick:Sensor,,"Measures the level of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Collection_Basin_Water_Temperature_Sensor,,,brick:Collection_Basin_Water,,,quantitykind:Temperature,brick:Sensor,,"Measures the temperature of the water in the collection basin, e.g. within a Cooling_Tower" +brick:Command,,,,,,,brick:Command,,A Command is an output point that directly determines the behavior of equipment and/or affects relevant operational points. +brick:Communication_Loss_Alarm,,,,,,,brick:Communication_Loss_Alarm,,An alarm that indicates a loss of communication e.g. with a device or controller +brick:Condensate_Leak_Alarm,,,brick:Condensate,,,,brick:Leak_Alarm,,An alarm that indicates a leak of condensate from a cooling system +brick:Condenser_Water_Flow_Sensor,,,brick:Condenser_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the condenser water +brick:Condenser_Water_Flow_Setpoint,,,brick:Condenser_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Condenser_Water_Temperature_Sensor,,,brick:Condenser_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of condenser water +brick:Conductivity_Sensor,,,,,,quantitykind:Conductivity,brick:Sensor,,Measures electrical conductance +brick:Contact_Sensor,,,,,,,,(deprecated),"Senses or detects contact, such as for determining if a door is closed." +brick:Cooling_Command,,brick:Cooling,,,,,brick:Command,,Controls the amount of cooling to be delivered (typically as a proportion of total cooling output) +brick:Cooling_Demand_Sensor,,brick:Cooling,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a cooling process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Cooling_Demand_Setpoint,,brick:Cooling,,,,,brick:Demand_Setpoint,,Sets the rate required for cooling +brick:Cooling_Discharge_Air_Flow_Setpoint,,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Cooling_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Discharge_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,(alias), +brick:Cooling_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Discharge_Air,,,quantitykind:Temperature,brick:Integral_Time_Parameter,(alias), +brick:Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Discharge_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,(alias), +brick:Cooling_Enable_Command,,brick:Cooling,,,,,brick:Enable_Command,,"Command that enables cooling functionality in equipment but certain condition(s) must be met first before actively cooling. For the actively cooling control, see Cooling_Command." +brick:Cooling_Mode_Status,,brick:Cooling,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a cooling mode" +brick:Cooling_Start_Stop_Status,,brick:Cooling,,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Cooling_Supply_Air_Flow_Setpoint,,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling +brick:Cooling_Supply_Air_Temperature_Deadband_Setpoint,,brick:Cooling,brick:Supply_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for cooling +brick:Cooling_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Cooling,brick:Supply_Air,,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Cooling_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Cooling,brick:Supply_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Cooling_Temperature_Setpoint,,brick:Cooling,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling +brick:Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,The cooling setpoint for a specific zone in a building. +brick:Core_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Core,Measures the internal temperature of the radiant layer at the heat source or sink level of the radiant heating and cooling HVAC system. +brick:Core_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Core,"Sets temperature for the core, i.e. the temperature at the heat source or sink level, of the radiant panel." +brick:Current_Imbalance_Sensor,,,,,,quantitykind:ElectricCurrentImbalance,brick:Sensor,,A sensor which measures the current difference (imbalance) between phases of an electrical system +brick:Current_Limit,,,,,,quantitykind:ElectricCurrent,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Current_Setpoint. +brick:Current_Output_Sensor,,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a device +brick:Current_Ratio_Setpoint,,,,,,quantitykind:ElectricCurrent,brick:Setpoint,Ratio,Sets the ratio of currents in a transformer +brick:Current_Sensor,,,,,,quantitykind:ElectricCurrent,brick:Sensor,,Senses the amperes of electrical current passing through the sensor +brick:Curtailment_Override_Command,,,,,,,,(deprecated), +brick:Cycle_Alarm,,,,,,,brick:Cycle_Alarm,,An alarm that indicates off-normal conditions associated with HVAC cycles +brick:Damper_Command,,brick:Damper,,,,,brick:Command,,Controls properties of dampers +brick:Damper_Position_Command,,brick:Damper,,,,quantitykind:OpeningRatio,brick:Command,,Controls the position (the degree of openness) of a damper +brick:Damper_Position_Sensor,,brick:Damper,,,,quantitykind:OpeningRatio,brick:Sensor,,Measures the current position of a damper in terms of the percent of fully open +brick:Damper_Position_Setpoint,,brick:Damper,,,,quantitykind:OpeningRatio,brick:Setpoint,,Sets the position of damper +brick:Damper_Position_Status,,brick:Damper,,,,quantitykind:OpeningRatio,brick:Status,, +brick:DC_Bus_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage across a DC bus +brick:Deadband_Setpoint,,,,,,,brick:Deadband_Setpoint,,Sets the size of a deadband +brick:Deceleration_Time_Setpoint,,brick:Deceleration,,,,quantitykind:Time,brick:Setpoint,, +brick:Dehumidification_Start_Stop_Status,,brick:Dehumidification,,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Dehumidify_Command,,brick:Dehumidification,,,,,brick:Enable_Command,,"Triggers the dehumidification process, actively removing moisture from the air to achieve desired humidity levels" +brick:Deionised_Water_Conductivity_Sensor,,,brick:Deionized_Water,,,quantitykind:Conductivity,brick:Sensor,,Measures the electrical conductance of deionised water +brick:Deionised_Water_Level_Sensor,,,brick:Deionized_Water,,,quantitykind:LiquidLevel,brick:Sensor,,Measures the height/level of deionised water in some container +brick:Deionized_Water_Alarm,,,brick:Deionized_Water,,,,brick:Leak_Alarm,,An alarm that indicates deionized water leaks. +brick:Delay_Parameter,,,,,,,brick:Delay_Parameter,,A parameter determining how long to delay a subsequent action to take place after a received signal +brick:Demand_Sensor,,,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by the use of some process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Demand_Setpoint,,,,,,,brick:Demand_Setpoint,,Sets the rate required for a process +brick:Derivative_Gain_Parameter,,,,,,,brick:Derivative_Gain_Parameter,, +brick:Derivative_Time_Parameter,,,,,,,brick:Derivative_Time_Parameter,, +brick:Dewpoint_Sensor,,,,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature . Dew point is the temperature to which air must be cooled to become saturated with water vapor +brick:Dewpoint_Setpoint,,,,,,quantitykind:DewPointTemperature,brick:Setpoint,,Sets dew point +brick:Differential_Air_Temperature_Setpoint,,,brick:Air,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets temperature of diffrential air +brick:Differential_Entering_Leaving_Water_Temperature_Sensor,,,,,,,,(deprecated),Measures the difference in temperature between entering and leaving water of water a circuit +brick:Differential_Pressure_Deadband_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure +brick:Differential_Pressure_Integral_Time_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Differential_Pressure_Load_Shed_Status,,,,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Status,, +brick:Differential_Pressure_Proportional_Band,,,,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Differential_Pressure_Sensor,,,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference between two applied pressures +brick:Differential_Pressure_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets differential pressure +brick:Differential_Pressure_Setpoint_Limit,,,,,brick:Differential,quantitykind:Pressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Differential_Pressure_Setpoint. +brick:Differential_Pressure_Step_Parameter,,,,,brick:Differential,quantitykind:Pressure,brick:Step_Parameter,, +brick:Differential_Setpoint,,,,,brick:Differential,,brick:Setpoint,,A type of Setpoints that is related to the difference between two measurements +brick:Differential_Speed_Sensor,,,,,brick:Differential,quantitykind:Speed,brick:Sensor,, +brick:Differential_Speed_Setpoint,,,,,brick:Differential,quantitykind:Speed,brick:Setpoint,,Sets differential speed +brick:Differential_Temperature_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,A type of Setpoints that is related to the difference between two temperature measurements +brick:Direction_Command,,,,,,,,(deprecated),Commands that affect the direction of some phenomenon +brick:Direction_Sensor,,,,,,,,(deprecated),Measures the direction in degrees in which a phenomenon is occuring +brick:Direction_Status,,,,,,,,(deprecated),Indicates which direction a device is operating in +brick:Disable_Command,,,,,,,brick:Disable_Command,,Commands that disable functionality +brick:Disable_Differential_Enthalpy_Command,,brick:Differential_Enthalpy,,,,,brick:Disable_Command,,Disables the use of differential enthalpy control +brick:Disable_Differential_Temperature_Command,,brick:Differential_Temperature,,,,,brick:Disable_Command,,Disables the use of differential temperature control +brick:Disable_Fixed_Enthalpy_Command,,brick:Fixed_Enthalpy,,,,,brick:Disable_Command,,Disables the use of fixed enthalpy control +brick:Disable_Fixed_Temperature_Command,,brick:Fixed_Temperature,,,,,brick:Disable_Command,,Disables the use of fixed temperature temperature +brick:Disable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated),Disables hot water system when outside air temperature reaches the indicated value +brick:Disable_Status,,,,,,,brick:Disable_Status,,Indicates if functionality has been disabled +brick:Discharge_Air_Dewpoint_Sensor,,,brick:Discharge_Air,,,quantitykind:DewPointTemperature,brick:Sensor,(alias), +brick:Discharge_Air_Differential_Pressure_Sensor,,,brick:Discharge_Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,(alias), +brick:Discharge_Air_Differential_Pressure_Setpoint,,,brick:Discharge_Air,,brick:Differential,quantitykind:Pressure,brick:Setpoint,(alias), +brick:Discharge_Air_Duct_Pressure_Status,,,,,,,,(deprecated) (alias), +brick:Discharge_Air_Flow_Demand_Setpoint,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,(alias), +brick:Discharge_Air_Flow_High_Reset_Setpoint,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,(alias), +brick:Discharge_Air_Flow_Low_Reset_Setpoint,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,(alias), +brick:Discharge_Air_Flow_Reset_Setpoint,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,(alias), +brick:Discharge_Air_Flow_Sensor,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,(alias), +brick:Discharge_Air_Flow_Setpoint,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Discharge_Air_Humidity_Sensor,,,brick:Discharge_Air,,,quantitykind:RelativeHumidity,brick:Sensor,(alias), +brick:Discharge_Air_Humidity_Setpoint,,,brick:Discharge_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,(alias), +brick:Discharge_Air_Integral_Gain_Parameter,,,brick:Discharge_Air,,,,brick:Integral_Gain_Parameter,(alias), +brick:Discharge_Air_Proportional_Gain_Parameter,,,brick:Discharge_Air,,,,brick:Proportional_Gain_Parameter,(alias), +brick:Discharge_Air_Smoke_Detection_Alarm,,,brick:Discharge_Air,,,,brick:Smoke_Detection_Alarm,(alias), +brick:Discharge_Air_Static_Pressure_Deadband_Setpoint,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,(alias), +brick:Discharge_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,(alias), +brick:Discharge_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,(alias), +brick:Discharge_Air_Static_Pressure_Sensor,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Sensor,(alias), +brick:Discharge_Air_Static_Pressure_Setpoint,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Setpoint,(alias), +brick:Discharge_Air_Static_Pressure_Step_Parameter,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Step_Parameter,(alias), +brick:Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Alarm,(alias), +brick:Discharge_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint,(alias), +brick:Discharge_Air_Temperature_Deadband_Setpoint,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,(alias), +brick:Discharge_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint,(alias), +brick:Discharge_Air_Temperature_High_Reset_Setpoint,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:High_Reset_Setpoint,(alias), +brick:Discharge_Air_Temperature_Low_Reset_Setpoint,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,(alias), +brick:Discharge_Air_Temperature_Proportional_Band_Parameter,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,(alias), +brick:Discharge_Air_Temperature_Reset_Differential_Setpoint,,,brick:Discharge_Air,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,(alias), +brick:Discharge_Air_Temperature_Sensor,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Sensor,(alias), +brick:Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint,(alias), +brick:Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint_Limit,(alias), +brick:Discharge_Air_Temperature_Step_Parameter,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Step_Parameter,(alias), +brick:Discharge_Air_Velocity_Pressure_Sensor,,,brick:Discharge_Air,,,quantitykind:DynamicPressure,brick:Sensor,(alias), +brick:Domestic_Hot_Water_Differential_Pressure_Sensor,,,brick:Domestic_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the pressure difference in domestic hot water systems. +brick:Domestic_Hot_Water_Differential_Pressure_Setpoint,,,brick:Domestic_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe used to carry domestic hot water +brick:Domestic_Hot_Water_System_Enable_Command,,brick:Domestic_Hot_Water_System,,,,,brick:Enable_Command,,Enables operation of the domestic hot water system +brick:Domestic_Hot_Water_Temperature_Sensor,,,brick:Domestic_Hot_Water,,,quantitykind:Temperature,brick:Sensor,, +brick:Domestic_Hot_Water_Temperature_Setpoint,,,brick:Domestic_Hot_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of domestic hot water +brick:Drive_Ready_Status,,,,,,,,(deprecated),"Indicates if a hard drive or other storage device is ready to be used, e.g. in the context of RAID" +brick:Duct_Air_Static_Pressure_Setpoint,,,,,,,,(deprecated), +brick:Duration_Sensor,,,,,,quantitykind:Time,brick:Sensor,,Measures the duration of a phenomenon or event +brick:EconCycle_Start_Stop_Status,,,,,,,,(deprecated), +brick:Effective_Air_Temperature_Setpoint,,,brick:Air,,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Cooling_Zone_Air_Temperature_Setpoint,,brick:Cooling,brick:Zone_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective cooling setpoint for a specific zone in a building. +brick:Effective_Discharge_Air_Temperature_Setpoint,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,(alias), +brick:Effective_Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,,The effective heating setpoint for a specific zone in a building. +brick:Effective_Return_Air_Temperature_Setpoint,,,brick:Return_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Room_Air_Temperature_Setpoint,,,brick:Room_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,, +brick:Effective_Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,,quantitykind:Temperature,brick:Effective_Setpoint,,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired air temperature in a specific zone of a building. This setpoint acts as a baseline from which the cooling and heating setpoints are established by adding or subtracting a deadband width +brick:Electric_Energy_Sensor,,,,,,quantitykind:ElectricEnergy,brick:Sensor,, +brick:Electric_Power_Sensor,,,,,,quantitykind:ElectricPower,brick:Sensor,,Measures the amount of instantaneous electric power consumed +brick:Electrical_Energy_Usage_Sensor,,,,,,quantitykind:ElectricEnergy,brick:Usage_Sensor,,A sensor that records the quantity of electrical energy consumed in a given period +brick:Embedded_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Embedded,Measures the internal temperature of the radiant layer of the radiant heating and cooling HVAC system. +brick:Embedded_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Embedded,"Sets temperature for the internal material, e.g. concrete slab, of the radiant panel." +brick:Emergency_Air_Flow_System_Status,,,,,,,,(deprecated), +brick:Emergency_Alarm,,,,,,,,(deprecated),Alarms that indicate off-normal conditions associated with emergency systems +brick:Emergency_Generator_Alarm,,,,,,,,(deprecated),An alarm that indicates off-normal conditions associated with an emergency generator +brick:Emergency_Generator_Status,,,,,,,,(deprecated),Indicates if an emergency generator is active +brick:Emergency_Power_Off_System_Activated_By_High_Temperature_Status,,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Activated_By_Leak_Detection_System_Status,,,,,,,,(deprecated), +brick:Emergency_Power_Off_System_Status,,,,,,,,(deprecated), +brick:Emergency_Push_Button_Status,,,,,,,,(deprecated),Indicates if an emergency button has been pushed +brick:Enable_Command,,,,,,,brick:Enable_Command,,Commands that enable functionality +brick:Enable_Differential_Enthalpy_Command,,brick:Differential_Enthalpy,,,,,brick:Enable_Command,,Enables the use of differential enthalpy control +brick:Enable_Differential_Temperature_Command,,brick:Differential_Temperature,,,,,brick:Enable_Command,,Enables the use of differential temperature control +brick:Enable_Fixed_Enthalpy_Command,,brick:Fixed_Enthalpy,,,,,brick:Enable_Command,,Enables the use of fixed enthalpy control +brick:Enable_Fixed_Temperature_Command,,brick:Fixed_Temperature,,,,,brick:Enable_Command,,Enables the use of fixed temperature control +brick:Enable_Hot_Water_System_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated),Enables hot water system when outside air temperature reaches the indicated value +brick:Enable_Status,,,,,,,brick:Enable_Status,,Indicates if a system or piece of functionality has been enabled +brick:Energy_Generation_Sensor,,,,,,quantitykind:Energy,brick:Generation_Sensor,,A sensor measuring the amount of generated energy. +brick:Energy_Sensor,,,,,,quantitykind:Energy,brick:Sensor,,Measures energy consumption +brick:Energy_Usage_Sensor,,,,,,quantitykind:Energy,brick:Usage_Sensor,,Measures the total amount of energy used over some period of time +brick:Entering_Chilled_Water_Flow_Sensor,,,brick:Entering_Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled entering water +brick:Entering_Chilled_Water_Flow_Setpoint,,,brick:Entering_Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled entering water +brick:Entering_Chilled_Water_Temperature_Sensor,,,brick:Entering_Chilled_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is entering a cooling tower +brick:Entering_Chilled_Water_Temperature_Setpoint,,,brick:Entering_Chilled_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the chilled water load) chilled water +brick:Entering_Condenser_Water_Flow_Sensor,,,brick:Entering_Condenser_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Sensor,,,brick:Entering_Condenser_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the entering condenser water +brick:Entering_Condenser_Water_Temperature_Setpoint,,,brick:Entering_Condenser_Water,,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the entering condenser water +brick:Entering_Domestic_Hot_Water_Temperature_Sensor,,,brick:Entering_Domestic_Hot_Water,,,quantitykind:Temperature,brick:Sensor,, +brick:Entering_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Entering_Domestic_Hot_Water,,,quantitykind:Temperature,brick:Setpoint,, +brick:Entering_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_High_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water entering a hot water system +brick:Entering_Hot_Water_Flow_Sensor,,,brick:Entering_Hot_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot entering water +brick:Entering_Hot_Water_Flow_Setpoint,,,brick:Entering_Hot_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot entering water +brick:Entering_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Hot_Water,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Load_Shed_Status,,,brick:Entering_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Status,, +brick:Entering_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Hot_Water,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Hot_Water_Temperature_Sensor,,,brick:Entering_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water entering a hot water system +brick:Entering_Hot_Water_Temperature_Setpoint,,,brick:Entering_Hot_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of entering (downstream of the hot water load) hot water +brick:Entering_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Entering_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Status,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Entering_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Entering_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Entering_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water entering a hot water system +brick:Entering_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Entering_Water,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of entering water +brick:Entering_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Entering_Water,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Entering_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Entering_Water,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Flow_Sensor,,,brick:Entering_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water entering a piece of equipment or system +brick:Entering_Water_Flow_Setpoint,,,brick:Entering_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of entering water +brick:Entering_Water_Pressure_Sensor,,,brick:Entering_Water,,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the entry point of a system. +brick:Entering_Water_Temperature_Alarm,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the entering water. +brick:Entering_Water_Temperature_Deadband_Setpoint,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of entering water +brick:Entering_Water_Temperature_Integral_Time_Parameter,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Entering_Water_Temperature_Proportional_Band_Parameter,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Entering_Water_Temperature_Sensor,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of entering water +brick:Entering_Water_Temperature_Setpoint,,,brick:Entering_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of entering water +brick:Enthalpy_Sensor,,,,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of some substance +brick:Enthalpy_Setpoint,,,,,,quantitykind:Enthalpy,brick:Setpoint,,Sets enthalpy +brick:Even_Month_Status,,,,,,,,(deprecated), +brick:Exhaust_Air_Dewpoint_Sensor,,,brick:Exhaust_Air,,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of exhaust air +brick:Exhaust_Air_Differential_Pressure_Sensor,,,brick:Exhaust_Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to exhaust air from the building +brick:Exhaust_Air_Differential_Pressure_Setpoint,,,brick:Exhaust_Air,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a exhaust air duct or conduit +brick:Exhaust_Air_Flow_Integral_Time_Parameter,,,brick:Exhaust_Air,,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Flow_Proportional_Band_Parameter,,,brick:Exhaust_Air,,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Flow_Sensor,,,brick:Exhaust_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of exhaust air +brick:Exhaust_Air_Flow_Setpoint,,,brick:Exhaust_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air flow rate +brick:Exhaust_Air_Humidity_Sensor,,,brick:Exhaust_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of exhaust air +brick:Exhaust_Air_Humidity_Setpoint,,,brick:Exhaust_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for exhaust air +brick:Exhaust_Air_Stack_Flow_Deadband_Setpoint,,brick:Exhaust_Air_Stack,brick:Air,,,quantitykind:VolumeFlowRate,brick:Deadband_Setpoint,,Sets the size of a deadband of exhaust air stack flow +brick:Exhaust_Air_Stack_Flow_Integral_Time_Parameter,,brick:Exhaust_Air_Stack,brick:Air,,,quantitykind:VolumeFlowRate,brick:Integral_Time_Parameter,, +brick:Exhaust_Air_Stack_Flow_Proportional_Band_Parameter,,brick:Exhaust_Air_Stack,brick:Air,,,quantitykind:VolumeFlowRate,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Stack_Flow_Sensor,,brick:Exhaust_Air_Stack,brick:Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in the exhaust air stack +brick:Exhaust_Air_Stack_Flow_Setpoint,,brick:Exhaust_Air_Stack,brick:Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets exhaust air stack flow rate +brick:Exhaust_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Exhaust_Air,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Exhaust_Air_Static_Pressure_Sensor,,,brick:Exhaust_Air,,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within exhaust regions of an HVAC system +brick:Exhaust_Air_Static_Pressure_Setpoint,,,brick:Exhaust_Air,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of exhaust air +brick:Exhaust_Air_Temperature_Sensor,,,brick:Exhaust_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of exhaust air +brick:Exhaust_Air_Velocity_Pressure_Sensor,,,brick:Exhaust_Air,,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Failure_Alarm,,,,,,,brick:Failure_Alarm,,"Alarms that indicate the failure of devices, equipment, systems and control loops" +brick:Fan_Command,,brick:Fan,,,,,brick:Command,,Controls properties of fans +brick:Fan_On_Off_Status,,brick:Fan,,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Fan_Speed_Command,,brick:Fan,,,,quantitykind:Speed,brick:Command,,Controls the speed of fans +brick:Fan_Status,,brick:Fan,,,,,brick:Status,,Indicates properties of fans +brick:Fault_Reset_Command,,,,,,,brick:Fault_Reset_Command,,Clears a fault status +brick:Fault_Status,,,,,,,brick:Fault_Status,,"Indicates the presence of a fault in a device, system or control loop" +brick:Filter_Air_Differential_Pressure_Sensor,,brick:Filter,brick:Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in air pressure before and after an air filter. +brick:Filter_Differential_Pressure_Sensor,,brick:Filter,,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure on either side of a filter +brick:Filter_Reset_Command,,brick:Filter,,,,,brick:Reset_Command,, +brick:Filter_Status,,brick:Filter,,,,,brick:Status,,Indicates if a filter needs to be replaced +brick:Filter_Water_Differential_Pressure_Sensor,,brick:Filter,brick:Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure before and after a water filter. +brick:Fire_Sensor,,,brick:Fire,,,,brick:Sensor,,Measures the presence of fire +brick:Flow_Sensor,,,,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of some substance +brick:Flow_Setpoint,,,,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets flow +brick:Formaldehyde_Level_Sensor,,,brick:Air,brick:Formaldehyde,,quantitykind:MassDensity,brick:Sensor,,Measures the concentration of formaldehyde in air +brick:Freeze_Status,,,,,,,,(deprecated),Indicates if a substance contained within a vessel has frozen +brick:Frequency_Command,,,,,,quantitykind:Frequency,brick:Command,,Controls the frequency of a device's operation (e.g. rotational frequency) +brick:Frequency_Sensor,,,,,,quantitykind:Frequency,brick:Sensor,,"Measures the frequency of a phenomenon or aspect of a phenomenon, e.g. the frequency of a fan turning" +brick:Frequency_Setpoint,,,,,,quantitykind:Frequency,brick:Setpoint,,Sets frequency +brick:Fresh_Air_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Frost_Sensor,,,brick:Frost,,,,brick:Sensor,,Senses the presence of frost or conditions that may cause frost +brick:Fume_Hood_Air_Flow_Sensor,,brick:Fume_Hood,brick:Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of air in a fume hood +brick:Gain_Parameter,,,,,,,brick:Gain_Parameter,, +brick:Gas_Sensor,,,brick:Gas,,,,brick:Sensor,,Measures gas concentration (other than CO2) +brick:Gauge_Pressure_Sensor,,,,,,quantitykind:GaugePressure,brick:Sensor,,Pressure sensor which is zero-referenced against ambient air pressure +brick:Generation_Sensor,,,,,,,brick:Generation_Sensor,,A sensor measuring how much something has been generated. +brick:Hail_Sensor,,,brick:Hail,,,,brick:Sensor,,Measures hail in terms of its size and damage potential +brick:Heat_Exchanger_Leaving_Water_Temperature_Sensor,,brick:Heat_Exchanger,brick:Leaving_Water,,,quantitykind:Temperature,brick:Sensor,, +brick:Heat_Exchanger_System_Enable_Status,,brick:Heat_Exchanger_System,,,,,brick:Enable_Status,,Indicates if the heat exchanger system has been enabled +brick:Heat_Sink_Temperature_Sensor,,,,,,,,(deprecated),Measure temperature of the heat sink on a device such as a VFD. +brick:Heating_Command,,brick:Heating,,,,,brick:Command,,Controls the amount of heating to be delivered (typically as a proportion of total heating output) +brick:Heating_Demand_Sensor,,brick:Heating,,,,,brick:Demand_Sensor,,Measures the amount of power consumed by a heating process; typically found by multiplying the tonnage of a unit (e.g. RTU) by the efficiency rating in kW/ton +brick:Heating_Demand_Setpoint,,brick:Heating,,,,,brick:Demand_Setpoint,,Sets the rate required for heating +brick:Heating_Discharge_Air_Flow_Setpoint,,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Heating_Discharge_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Discharge_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,(alias), +brick:Heating_Discharge_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Discharge_Air,,,quantitykind:Temperature,brick:Integral_Time_Parameter,(alias), +brick:Heating_Discharge_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Discharge_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,(alias), +brick:Heating_Enable_Command,,brick:Heating,,,,,brick:Enable_Command,,"Command that enables heating functionality in equipment but certain condition(s) must be met first before actively heating. For the actively heating control, see Heating_Command." +brick:Heating_Mode_Status,,brick:Heating,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in a heating mode" +brick:Heating_Start_Stop_Status,,brick:Heating,,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Heating_Supply_Air_Flow_Setpoint,,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating +brick:Heating_Supply_Air_Temperature_Deadband_Setpoint,,brick:Heating,brick:Supply_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air for heating +brick:Heating_Supply_Air_Temperature_Integral_Time_Parameter,,brick:Heating,brick:Supply_Air,,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Heating_Supply_Air_Temperature_Proportional_Band_Parameter,,brick:Heating,brick:Supply_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Heating_Temperature_Setpoint,,brick:Heating,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating +brick:Heating_Thermal_Power_Sensor,,brick:Heating,,,,quantitykind:ThermalPower,brick:Sensor,, +brick:Heating_Zone_Air_Temperature_Setpoint,,brick:Heating,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,The heating setpoint for a specific zone in a building. +brick:High_Air_Flow_Alarm,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:High_Alarm,,An alarm that indicates that the air flow is higher than normal. +brick:High_CO2_Alarm,,,brick:Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:High_Alarm,,A device that indicates high concentration of carbon dioxide. +brick:High_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:High_Alarm,(alias), +brick:High_Head_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a high pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. +brick:High_Humidity_Alarm,,,brick:Air,,,quantitykind:RelativeHumidity,brick:High_Alarm,,An alarm that indicates high concentration of water vapor in the air. +brick:High_Humidity_Alarm_Parameter,,,brick:Air,,,quantitykind:RelativeHumidity,brick:High_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a high humidity alarm +brick:High_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,,(deprecated),The upper bound of the outside air temperature lockout range +brick:High_Return_Air_Temperature_Alarm,,,brick:Return_Air,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that return air temperature is too high +brick:High_Static_Pressure_Cutout_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a High_Static_Pressure_Cutout_Setpoint. +brick:High_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates that supply air temperature is too high +brick:High_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:High_Alarm,,An alarm that indicates high temperature. +brick:High_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:High_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a high temperature alarm +brick:Hold_Status,,,,,,,,(deprecated), +brick:Hot_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of hot water +brick:Hot_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Reset_Status,, +brick:Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Status,, +brick:Hot_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Hot_Water_Differential_Pressure_Sensor,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure on either side of a hot water valve +brick:Hot_Water_Differential_Pressure_Setpoint,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit used to carry hot water +brick:Hot_Water_Differential_Temperature_Sensor,,,brick:Hot_Water,,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in temperature between the entering water to the boiler or other water heating device and leaving water from the same boiler or other water heating device +brick:Hot_Water_Flow_Sensor,,,brick:Hot_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow in a hot water circuit +brick:Hot_Water_Flow_Setpoint,,,brick:Hot_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot water +brick:Hot_Water_Gauge_Pressure_Sensor,,,brick:Hot_Water,,,quantitykind:GaugePressure,brick:Sensor,,Sensor measuring the gauge pressure (zero-referenced against ambient air pressure) of hot water +brick:Hot_Water_Static_Pressure_Setpoint,,,brick:Hot_Water,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of hot air +brick:Hot_Water_System_Enable_Command,,brick:Hot_Water_System,,,,,brick:Enable_Command,,Enables operation of the hot water system +brick:Hot_Water_Temperature_Setpoint,,,brick:Hot_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets the temperature of hot water +brick:Hot_Water_Usage_Sensor,,,brick:Hot_Water,,,,brick:Usage_Sensor,,"Measures the amount of hot water that is consumed, over some period of time" +brick:Humidification_Start_Stop_Status,,brick:Humidification,,,,brick:EnumerationKind-Start_Stop,brick:Status,, +brick:Humidifier_Fault_Status,,brick:Humidifier,,,,,brick:Fault_Status,,Indicates the presence of a fault in a humidifier +brick:Humidify_Command,,brick:Humidification,,,,,brick:Enable_Command,, +brick:Humidity_Alarm,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the concentration of water vapor in the air. +brick:Humidity_Deadband_Setpoint,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Deadband_Setpoint,,Sets the size of a deadband of humidity +brick:Humidity_Parameter,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Parameter,,Parameters relevant to humidity-related systems and points +brick:Humidity_Sensor,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the concentration of water vapor in air +brick:Humidity_Setpoint,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Sets humidity +brick:Humidity_Tolerance_Parameter,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of humidity. +brick:Ice_Tank_Leaving_Water_Temperature_Sensor,,brick:Ice_Tank,brick:Leaving_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving an ice tank +brick:Illuminance_Sensor,,,,,,quantitykind:Illuminance,brick:Sensor,,"Measures the total luminous flux incident on a surface, per unit area" +brick:Illuminance_Setpoint,,,,,,quantitykind:Illuminance,brick:Setpoint,,Target Illuminance of the zone. +brick:Imbalance_Sensor,,,,,,,,(deprecated),A sensor which measures difference (imbalance) between phases of an electrical system +brick:Inside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Inside Face Surface,Measures the inside surface (relative to the space) of the radiant panel of the radiant heating and cooling HVAC system. +brick:Inside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Inside Face Surface,Sets temperature for the inside face surface temperature of the radiant panel. +brick:Intake_Air_Temperature_Sensor,,,,,,,,(deprecated),Measures air at the interface between the building and the outside +brick:Integral_Gain_Parameter,,,,,,,brick:Integral_Gain_Parameter,, +brick:Integral_Time_Parameter,,,,,,,brick:Integral_Time_Parameter,, +brick:Last_Fault_Code_Status,,,,,,,,(deprecated),Indicates the last fault code that occurred +brick:Lead_Lag_Command,,,,,,,brick:Command,Lead Lag,Enables lead/lag operation +brick:Lead_Lag_Status,,,,,,,brick:Status,Lead Lag,Indicates if lead/lag operation is enabled +brick:Lead_On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,Lead,"Controls the active/inactive status of the ""lead"" part of a lead/lag system" +brick:Leak_Alarm,,,,,,,brick:Leak_Alarm,,An alarm that indicates leaks occured in systems containing fluids +brick:Leaving_Chilled_Water_Flow_Sensor,,,brick:Leaving_Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of chilled leaving water +brick:Leaving_Chilled_Water_Flow_Setpoint,,,brick:Leaving_Chilled_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of chilled leaving water +brick:Leaving_Chilled_Water_Temperature_Sensor,,,brick:Leaving_Chilled_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of chilled water that is supplied from a chiller +brick:Leaving_Chilled_Water_Temperature_Setpoint,,,brick:Leaving_Chilled_Water,,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving chilled water +brick:Leaving_Condenser_Water_Flow_Sensor,,,brick:Leaving_Condenser_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the flow of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Sensor,,,brick:Leaving_Condenser_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the leaving condenser water +brick:Leaving_Condenser_Water_Temperature_Setpoint,,,brick:Leaving_Condenser_Water,,,quantitykind:Temperature,brick:Setpoint,,The temperature setpoint for the leaving condenser water +brick:Leaving_Domestic_Hot_Water_Temperature_Sensor,,,brick:Leaving_Domestic_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of domestic water supplied by a hot water system +brick:Leaving_Domestic_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Domestic_Hot_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leavinging part of domestic hot water +brick:Leaving_High_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_High_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of high-temperature hot water supplied by a hot water system +brick:Leaving_Hot_Water_Flow_Sensor,,,brick:Leaving_Hot_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of hot leaving water +brick:Leaving_Hot_Water_Flow_Setpoint,,,brick:Leaving_Hot_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of hot leaving water +brick:Leaving_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Hot_Water,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Load_Shed_Status,,,brick:Leaving_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Status,, +brick:Leaving_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Hot_Water,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Hot_Water_Temperature_Sensor,,,brick:Leaving_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water supplied by a hot water system +brick:Leaving_Hot_Water_Temperature_Setpoint,,,brick:Leaving_Hot_Water,,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for leaving hot water +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_High_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Load_Shed_Status,,,brick:Leaving_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Load_Shed_Status,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Low_Reset_Setpoint,,,brick:Leaving_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Leaving_Medium_Temperature_Hot_Water_Temperature_Sensor,,,brick:Leaving_Medium_Temperature_Hot_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of medium-temperature hot water supplied by a hot water system +brick:Leaving_Water_Differential_Pressure_Deadband_Setpoint,,,brick:Leaving_Water,,brick:Differential,quantitykind:Pressure,brick:Deadband_Setpoint,,Sets the size of a deadband of differential pressure of leaving water +brick:Leaving_Water_Differential_Pressure_Integral_Time_Parameter,,,brick:Leaving_Water,,brick:Differential,quantitykind:Pressure,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Differential_Pressure_Proportional_Band_Parameter,,,brick:Leaving_Water,,brick:Differential,quantitykind:Pressure,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Flow_Sensor,,,brick:Leaving_Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water that is leaving a piece of equipment or system +brick:Leaving_Water_Flow_Setpoint,,,brick:Leaving_Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of leaving water +brick:Leaving_Water_Pressure_Sensor,,,brick:Leaving_Water,,,quantitykind:Pressure,brick:Sensor,,Measures the water pressure at the exit point of a system. +brick:Leaving_Water_Temperature_Alarm,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of the leaving water. +brick:Leaving_Water_Temperature_Deadband_Setpoint,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of leaving water +brick:Leaving_Water_Temperature_Integral_Time_Parameter,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Integral_Time_Parameter,, +brick:Leaving_Water_Temperature_Proportional_Band_Parameter,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Leaving_Water_Temperature_Sensor,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water leaving a piece of equipment or system +brick:Leaving_Water_Temperature_Setpoint,,,brick:Leaving_Water,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of leaving water +brick:Level_Command,,,,,,,brick:Command,Level,Adjusts the operational state to a specific level within a predefined range. +brick:Level_Status,,,,,,,brick:Status,Level,The current operational state of a specific level within a predefined range. +brick:Lighting_Correlated_Color_Temperature_Command,,brick:Lighting,,,,quantitykind:CorrelatedColorTemperature,brick:Command,,A command to set correlated color temperature (CCT) which is the temperature of the Planckian radiator whose perceived color most closely resembles that of a given stimulus at the same brightness and under specified viewing conditions. +brick:Lighting_Level_Command,,brick:Lighting,,,,,brick:Command,Level,Controls the amount of the light provided by the device typically in percentages. +brick:Limit,,,,,,,brick:Limit,,A parameter that places an upper or lower bound on the range of permitted values of another point +brick:Liquid_Detection_Alarm,,,,,,,brick:Liquid_Detection_Alarm,, +brick:Load_Current_Sensor,,,,,,,,(deprecated),Measures the current consumed by a load +brick:Load_Parameter,,,,,,,,(deprecated), +brick:Load_Setpoint,,,,,,,,(deprecated), +brick:Load_Shed_Command,,,,,,,brick:Load_Shed_Command,,Controls load shedding behavior provided by a control system +brick:Load_Shed_Differential_Pressure_Setpoint,,,,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Setpoint,, +brick:Load_Shed_Setpoint,,,,,,,brick:Load_Shed_Setpoint,, +brick:Load_Shed_Status,,,,,,,brick:Load_Shed_Status,,Indicates if a load shedding policy is in effect +brick:Locally_On_Off_Status,,,,,,,,(deprecated), +brick:Lockout_Status,,,,,,,,(deprecated),"Indicates if a piece of equipment, system, or functionality has been locked out from operation" +brick:Lockout_Temperature_Differential_Parameter,,,,,,,,(deprecated), +brick:Low_Air_Flow_Alarm,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the air flow is lower than normal. +brick:Low_Battery_Alarm,,,,,,,brick:Low_Battery_Alarm,,An alarm that indicates the battery is low. +brick:Low_Discharge_Air_Flow_Alarm,,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Low_Alarm,(alias), +brick:Low_Discharge_Air_Temperature_Alarm,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Low_Alarm,(alias), +brick:Low_Freeze_Protect_Temperature_Parameter,,,,,,,,(deprecated), +brick:Low_Humidity_Alarm,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Low_Alarm,,An alarm that indicates low concentration of water vapor in the air. +brick:Low_Humidity_Alarm_Parameter,,,brick:Air,,,quantitykind:RelativeHumidity,brick:Low_Alarm_Parameter,,A parameter determining the humidity level at which to trigger a low humidity alarm +brick:Low_Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,,(deprecated),The lower bound of the outside air temperature lockout range +brick:Low_Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), +brick:Low_Outside_Air_Temperature_Enable_Setpoint,,,,,,,,(deprecated), +brick:Low_Return_Air_Temperature_Alarm,,,brick:Return_Air,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates that return air temperature is too low +brick:Low_Suction_Pressure_Alarm,,,,,,,,(deprecated),An alarm that indicates a low suction pressure in the compressor in a refrigeration or air conditioning system. +brick:Low_Supply_Air_Flow_Alarm,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Low_Alarm,,An alarm that indicates that the supply air flow is lower than normal. +brick:Low_Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Low_Alarm,, +brick:Low_Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Low_Alarm,,An alarm that indicates low temperature. +brick:Low_Temperature_Alarm_Parameter,,,,,,quantitykind:Temperature,brick:Low_Alarm_Parameter,,A parameter determining the temperature level at which to trigger a low temperature alarm +brick:Low_Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Low_Alarm,,An alarm that indicates the voltage is lower than its normal state. +brick:Lowest_Exhaust_Air_Static_Pressure_Sensor,,,,,,,,(deprecated),The lowest observed static pressure of air in exhaust regions of an HVAC system over some period of time +brick:Luminance_Alarm,,,,,,quantitykind:Luminance,brick:Alarm,, +brick:Luminance_Command,,,,,,quantitykind:Luminance,brick:Command,,Controls the amount of luminance delivered by a lighting system +brick:Luminance_Sensor,,,,,,quantitykind:Luminance,brick:Sensor,,Measures the luminous intensity per unit area of light travelling in a given direction +brick:Luminance_Setpoint,,,,,,quantitykind:Luminance,brick:Setpoint,,Sets luminance +brick:Maintenance_Mode_Command,,,,,,brick:EnumerationKind-Maintenance_Mode,brick:Command,,"Controls whether or not a device or controller is operating in ""Maintenance"" mode" +brick:Maintenance_Required_Alarm,,,,,,,brick:Maintenance_Required_Alarm,,An alarm that indicates that repair/maintenance is required on an associated device or equipment +brick:Manual_Auto_Status,,,,,,brick:EnumerationKind-Manual_Auto,brick:Status,,Indicates if a system is under manual or automatic operation +brick:Max_Air_Flow_Setpoint_Limit,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Max_Air_Temperature_Setpoint,,,,,,,,(deprecated),Setpoint for maximum air temperature +brick:Max_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Max_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Max_Limit,(alias), +brick:Max_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Max_Limit,(alias), +brick:Max_Frequency_Command,,,,,,,,(deprecated),Sets the maximum permitted frequency +brick:Max_Fresh_Air_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places an upper bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Max_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Max_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Max_Limit,,,,,,,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Setpoint. +brick:Max_Load_Setpoint,,,,,,,,(deprecated), +brick:Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Max_Position_Setpoint_Limit,,,,,,quantitykind:OpeningRatio,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Position_Setpoint. +brick:Max_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Speed_Setpoint. +brick:Max_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Max_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Max_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Max_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Temperature_Setpoint. +brick:Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,(alias), +brick:Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Max_Limit,,A parameter that places an upper bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Max_Water_Level_Alarm,,,brick:Water,,,quantitykind:LiquidLevel,brick:Max_Alarm,,Alarm indicating that the maximum water level was reached +brick:Max_Water_Temperature_Setpoint,,,,,,,,(deprecated),Setpoint for max water temperature +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Reset_Status,,,brick:Medium_Temperature_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Reset_Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Setpoint,,,brick:Medium_Temperature_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Setpoint,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Load_Shed_Status,,,brick:Medium_Temperature_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Load_Shed_Status,, +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Sensor,,,brick:Medium_Temperature_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between sections of a medium temperature hot water system +brick:Medium_Temperature_Hot_Water_Differential_Pressure_Setpoint,,,brick:Medium_Temperature_Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Setpoint,, +brick:Methane_Level_Sensor,,,brick:Air,brick:Methane,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of methane in air +brick:Min_Air_Flow_Setpoint_Limit,,,brick:Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Air_Flow_Setpoint. +brick:Min_Air_Temperature_Setpoint,,,,,,,,(deprecated),Setpoint for minimum air temperature +brick:Min_Chilled_Water_Differential_Pressure_Setpoint_Limit,,,brick:Chilled_Water,,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Chilled_Water_Differential_Pressure_Setpoint. +brick:Min_Cooling_Discharge_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Cooling_Supply_Air_Flow_Setpoint_Limit,,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Discharge_Air_Static_Pressure_Setpoint_Limit,,,brick:Discharge_Air,,,quantitykind:StaticPressure,brick:Min_Limit,(alias), +brick:Min_Discharge_Air_Temperature_Setpoint_Limit,,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Min_Limit,(alias), +brick:Min_Frequency_Command,,,,,,,,(deprecated), +brick:Min_Fresh_Air_Setpoint_Limit,,,,,,,,(deprecated),A parameter that places a lower bound on the range of permitted values of a Fresh_Air_Setpoint. +brick:Min_Heating_Discharge_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Heating_Supply_Air_Flow_Setpoint_Limit,,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Heating_Supply_Air_Flow_Setpoint. +brick:Min_Hot_Water_Differential_Pressure_Setpoint_Limit,,,brick:Hot_Water,,brick:Differential,quantitykind:Pressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Hot_Water_Differential_Pressure_Setpoint. +brick:Min_Limit,,,,,,,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Setpoint. +brick:Min_Load_Setpoint,,,,,,,,(deprecated), +brick:Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Occupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Occupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Outside_Air_Flow_Setpoint_Limit,,,brick:Outside_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Outside_Air_Flow_Setpoint. +brick:Min_Position_Setpoint_Limit,,,,,,quantitykind:OpeningRatio,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Position_Setpoint. +brick:Min_Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Speed_Setpoint. +brick:Min_Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Min_Supply_Air_Static_Pressure_Setpoint_Limit,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Static_Pressure_Setpoint. +brick:Min_Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Min_Temperature_Setpoint_Limit,,,,,,quantitykind:Temperature,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Temperature_Setpoint. +brick:Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Cooling_Supply_Air_Flow_Setpoint. +brick:Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,(alias), +brick:Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit,brick:Unoccupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Min_Limit,,A parameter that places a lower bound on the range of permitted values of a Unoccupied_Heating_Supply_Air_Flow_Setpoint. +brick:Min_Water_Level_Alarm,,,brick:Water,,,quantitykind:LiquidLevel,brick:Min_Alarm,,Alarm indicating that the minimum water level was reached +brick:Min_Water_Temperature_Setpoint,,,,,,,,(deprecated),Setpoint for min water temperature +brick:Mixed_Air_Flow_Sensor,,,brick:Mixed_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of mixed air +brick:Mixed_Air_Humidity_Sensor,,,brick:Mixed_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the humidity of mixed air +brick:Mixed_Air_Humidity_Setpoint,,,brick:Mixed_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for mixed air +brick:Mixed_Air_Temperature_Sensor,,,brick:Mixed_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of mixed air +brick:Mixed_Air_Temperature_Setpoint,,,brick:Mixed_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of mixed air +brick:Mode_Command,,,,,,brick:EnumerationKind-Mode,brick:Command,,Controls the operating mode of a device or controller +brick:Mode_Status,,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates which mode a system, device or control loop is currently in" +brick:Motion_Sensor,,,,,,brick:EnumerationKind-Motion,brick:Sensor,,Detects the presence of motion in some area +brick:Motor_Current_Sensor,,brick:Motor,,,,quantitykind:ElectricCurrent,brick:Sensor,,Measures the current consumed by a motor +brick:Motor_Direction_Status,,brick:Motor,,,,brick:EnumerationKind-Forward_Reverse,brick:Status,,"Indicates which direction a motor is operating in, e.g. forward or reverse" +brick:Motor_On_Off_Status,,brick:Motor,,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Motor_Speed_Sensor,,brick:Motor,,,,quantitykind:Speed,brick:Sensor,, +brick:Motor_Torque_Sensor,,brick:Motor,,,,quantitykind:Torque,brick:Sensor,,"Measures the torque, or rotating power, of a motor" +brick:Natural_Gas_Flow_Sensor,,,brick:Natural_Gas,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of natural gas +brick:Natural_Gas_Temperature_Sensor,,,brick:Natural_Gas,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of natural gas +brick:Natural_Gas_Usage_Sensor,,,brick:Natural_Gas,,,,brick:Usage_Sensor,,"Measures the amount of natural gas that is consumed or used, over some period of time" +brick:No_Water_Alarm,,,,,,,,(deprecated),Alarm indicating that there is no water in the equipment or system +brick:NO2_Level_Sensor,,,brick:Air,brick:NO2,,quantitykind:MassDensity,brick:Sensor,,Measures the concentration of NO2 in air +brick:Occupancy_Command,,,,,,brick:EnumerationKind-Occupancy,brick:Command,,"Controls whether or not a device or controller is operating in ""Occupied"" mode" +brick:Occupancy_Count_Sensor,,,,,,quantitykind:Population,brick:Sensor,,Sensors measuring the number of people in an area +brick:Occupancy_Sensor,,,,,,brick:EnumerationKind-Occupancy,brick:Sensor,,Detects occupancy of some space or area +brick:Occupancy_Status,,,,,,brick:EnumerationKind-Occupancy,brick:Status,,Indicates if a room or space is occupied +brick:Occupied_Air_Temperature_Setpoint,brick:Occupied,,brick:Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Occupied_Cooling_Mode_Status,brick:Occupied,brick:Cooling,,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Cooling_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for cooling when occupied +brick:Occupied_Cooling_Temperature_Deadband_Setpoint,brick:Occupied,brick:Cooling,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for cooling when occupied +brick:Occupied_Cooling_Temperature_Setpoint,brick:Occupied,brick:Cooling,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for cooling when occupied +brick:Occupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Cooling,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air cooling when occupied +brick:Occupied_Discharge_Air_Flow_Setpoint,brick:Occupied,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Occupied_Discharge_Air_Temperature_Setpoint,brick:Occupied,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint,(alias), +brick:Occupied_Heating_Discharge_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Occupied_Heating_Mode_Status,brick:Occupied,brick:Heating,,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Occupied_Heating_Supply_Air_Flow_Setpoint,brick:Occupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate for heating when occupied +brick:Occupied_Heating_Temperature_Deadband_Setpoint,brick:Occupied,brick:Heating,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature for heating when occupied +brick:Occupied_Heating_Temperature_Setpoint,brick:Occupied,brick:Heating,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for heating when occupied +brick:Occupied_Heating_Zone_Air_Temperature_Setpoint,brick:Occupied,brick:Heating,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature for zone air heating when occupied +brick:Occupied_Humidity_Setpoint,brick:Occupied,,brick:Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is occupied. +brick:Occupied_Load_Shed_Command,brick:Occupied,,,,,,brick:Load_Shed_Command,, +brick:Occupied_Mode_Status,brick:Occupied,,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates if a system, device or control loop is in ""Occupied"" mode" +brick:Occupied_Return_Air_Temperature_Setpoint,brick:Occupied,,brick:Return_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Room_Air_Temperature_Setpoint,brick:Occupied,,brick:Room_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Supply_Air_Flow_Setpoint,brick:Occupied,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate when occupied +brick:Occupied_Supply_Air_Temperature_Setpoint,brick:Occupied,,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Occupied_Target_Zone_Air_Temperature_Setpoint,brick:Occupied,,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired occupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Off_Command,,,,,,brick:EnumerationKind-Off,brick:Command,,"An Off Command controls or reports the binary 'off' status of a control loop, relay or equipment activity. It can only be used to stop/deactivate an associated equipment or process, or determine that the related entity is 'off'" +brick:Off_Status,,,,,,brick:EnumerationKind-Off,brick:Status,,"Indicates if a control loop, relay or equipment is off" +brick:On_Command,,,,,,brick:EnumerationKind-On,brick:Command,,"An On Command controls or reports the binary 'on' status of a control loop, relay or equipment activity. It can only be used to start/activate an associated equipment or process, or determine that the related entity is 'on'" +brick:On_Off_Command,,,,,,brick:EnumerationKind-On_Off,brick:Command,,"An On/Off Command controls or reports the binary status of a control loop, relay or equipment activity" +brick:On_Off_Status,,,,,,brick:EnumerationKind-On_Off,brick:Status,,"Indicates the on/off status of a control loop, relay or equipment" +brick:On_Status,,,,,,brick:EnumerationKind-On,brick:Status,,"Indicates if a control loop, relay or equipment is on" +brick:On_Timer_Sensor,,,,,,,,(deprecated),"Measures the duration for which a device was in an active or ""on"" state" +brick:Open_Close_Command,,,,,,brick:EnumerationKind-Open_Close,brick:Command,,"A binary signal given to a device, such as a damper or valve, to either open or close" +brick:Open_Close_Status,,,,,,brick:EnumerationKind-Open_Close,brick:Status,,Indicates the open/close status of a device such as a damper or valve +brick:Open_Heating_Valve_Outside_Air_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Operating_Mode_Status,,,,,,brick:EnumerationKind-Operating_Mode,brick:Status,,"Indicates the current operating mode of a system, device or control loop" +brick:Output_Frequency_Sensor,,,,,,,,(deprecated), +brick:Output_Voltage_Sensor,,,,,,,,(deprecated),Measures the voltage output by some process or device +brick:Outside_Air_CO_Sensor,,,brick:Outside_Air,brick:CO,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO in outside air +brick:Outside_Air_CO2_Sensor,,,brick:Outside_Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO2 in outside air +brick:Outside_Air_Dewpoint_Sensor,,,brick:Outside_Air,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of outside air +brick:Outside_Air_Enthalpy_Sensor,,,brick:Outside_Air,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of outside air +brick:Outside_Air_Flow_Sensor,,,brick:Outside_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of outside air into the system +brick:Outside_Air_Flow_Setpoint,,,brick:Outside_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets outside air flow rate +brick:Outside_Air_Grains_Sensor,,,brick:Outside_Air,,,quantitykind:SpecificHumidity,brick:Sensor,,Measures the mass of water vapor in outside air +brick:Outside_Air_Humidity_Sensor,,,brick:Outside_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of outside air +brick:Outside_Air_Humidity_Setpoint,,,brick:Outside_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for outside air +brick:Outside_Air_Lockout_Temperature_Differential_Parameter,,,,,,,,(deprecated), +brick:Outside_Air_Lockout_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Outside_Air_Temperature_Enable_Differential_Sensor,,,,,,,,(deprecated), +brick:Outside_Air_Temperature_High_Reset_Setpoint,,,brick:Outside_Air,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Outside_Air_Temperature_Low_Reset_Setpoint,,,brick:Outside_Air,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Outside_Air_Temperature_Sensor,,,brick:Outside_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of outside air +brick:Outside_Air_Temperature_Setpoint,,,brick:Outside_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of outside air +brick:Outside_Air_Wet_Bulb_Temperature_Sensor,,,brick:Outside_Air,,,quantitykind:WetBulbTemperature,brick:Sensor,,A sensor measuring the wet-bulb temperature of outside air +brick:Outside_Face_Surface_Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,Outside Face Surface,Measures the outside surface (relative to the space) of the radiant panel of a radiant heating and cooling HVAC system. +brick:Outside_Face_Surface_Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,Outside Face Surface,Sets temperature for the outside face surface temperature of the radiant panel. +brick:Outside_Illuminance_Sensor,,,,,,,,(deprecated),"Measures the total luminous flux incident on an outside, per unit area" +brick:Overload_Alarm,,,,,,,,(deprecated),An alarm that can indicate when a full-load current is exceeded. +brick:Overridden_Off_Status,,,,,,,,(deprecated),"Indicates if a control loop, relay or equipment has been turned off when it would otherwise be scheduled to be on" +brick:Overridden_On_Status,,,,,,,,(deprecated),"Indicates if a control loop, relay or equipment has been turned on when it would otherwise be scheduled to be off" +brick:Overridden_Status,,,,,,,,(deprecated),Indicates if the expected operating status of an equipment or control loop has been overridden +brick:Override_Command,,,,,,,,(deprecated),Controls or reports whether or not a device or control loop is in 'override' +brick:Ozone_Level_Sensor,,,brick:Air,brick:Ozone,,quantitykind:MassDensity,brick:Sensor,,Measures the concentration of ozone in air +brick:Parameter,,,,,,,brick:Parameter,,Parameter points are configuration settings used to guide the operation of equipment and control systems; for example they may provide bounds on valid setpoint values +brick:Particulate_Matter_Sensor,,,brick:Particulate_Matter,,,,brick:Sensor,,Detects pollutants in the ambient air +brick:Peak_Demand_Sensor,,,,,,,,(deprecated),The peak power consumed by a process over some period of time +brick:Photovoltaic_Current_Output_Sensor,,,,,,,,(deprecated),Senses the amperes of electrical current produced as output by a photovoltaic device +brick:PID_Parameter,,,,,,,brick:PID_Parameter,, +brick:Piezoelectric_Sensor,,,,,,,,(deprecated),"Senses changes pressure, acceleration, temperature, force or strain via the piezoelectric effect" +brick:PIR_Sensor,,,,,,,,(deprecated),Detects the presense of motion in some area using the differential change in infrared intensity between two or more receptors +brick:PM1_Level_Sensor,,,brick:PM1,,,quantitykind:MassDensity,brick:Sensor,,Detects level of particulates of size 1 microns +brick:PM1_Sensor,,,brick:PM1,,,quantitykind:MassDensity,brick:Sensor,,Detects matter of size 1 micron +brick:PM2.5_Level_Sensor,,,brick:PM2.5,,,quantitykind:MassDensity,brick:Sensor,,Detects level of particulates of size 2.5 microns +brick:PM2.5_Sensor,,,brick:PM2.5,,,quantitykind:MassDensity,brick:Sensor,,Detects matter of size 2.5 microns +brick:PM10_Level_Sensor,,,brick:PM10,,,quantitykind:MassDensity,brick:Sensor,,Detects level of particulates of size 10 microns +brick:PM10_Sensor,,,brick:PM10,,,quantitykind:MassDensity,brick:Sensor,,Detects matter of size 10 microns +brick:Position_Command,,,,,,quantitykind:OpeningRatio,brick:Command,,Controls or reports the position of some object +brick:Position_Limit,,,,,,quantitykind:OpeningRatio,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Position_Setpoint. +brick:Position_Sensor,,,,,,quantitykind:OpeningRatio,brick:Sensor,,Measures the current position of a component in terms of a fraction of its full range of motion +brick:Power_Alarm,,,,,,quantitykind:Power,brick:Alarm,,An alarm that indicates the off-normal conditions associated with electrical power. +brick:Power_Cycle_Count_Sensor,,brick:Power_Cycle,,,,quantitykind:Count,brick:Sensor,,Counts the number of equipment power cycles +brick:Power_Factor_Sensor,,,,,,quantitykind:PowerFactor,brick:Sensor,,"Sensors measuring power Factor, under periodic conditions, is the ratio of the absolute value of the active power (P) to the apparent power (S)." +brick:Power_Loss_Alarm,,,,,,,brick:Power_Loss_Alarm,,An alarm that indicates a power failure. +brick:Power_Sensor,,,,,,quantitykind:Power,brick:Sensor,,Measures the amount of instantaneous power consumed +brick:Pre_Filter_Status,,brick:Pre_Filter,,,,,brick:Status,,Indicates if a prefilter needs to be replaced +brick:Preheat_Command,,brick:Preheat,,,,,brick:Command,,A command to activate preheating. Typically used to preheat cool air coming from a mixing box or economizer +brick:Preheat_Demand_Setpoint,,brick:Preheat,,,,,brick:Demand_Setpoint,,Sets the rate required for preheat +brick:Preheat_Discharge_Air_Temperature_Sensor,,brick:Preheat,brick:Discharge_Air,,,quantitykind:Temperature,brick:Sensor,(alias), +brick:Preheat_Supply_Air_Temperature_Sensor,,brick:Preheat,brick:Supply_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air before it is heated +brick:Pressure_Alarm,,,,,,quantitykind:Pressure,brick:Alarm,,An alarm that indicates the off-normal conditions associated with pressure. +brick:Pressure_Sensor,,,,,,quantitykind:Pressure,brick:Sensor,,Measure the amount of force acting on a unit area +brick:Pressure_Setpoint,,,,,,quantitykind:Pressure,brick:Setpoint,,Sets pressure +brick:Pressure_Status,,,,,,quantitykind:Pressure,brick:Status,,Indicates if pressure is within expected bounds +brick:Proportional_Band_Parameter,,,,,,,brick:Proportional_Band_Parameter,, +brick:Proportional_Gain_Parameter,,,,,,,brick:Proportional_Gain_Parameter,, +brick:Pump_Command,,brick:Pump,,,,,brick:Command,,Controls or reports the speed of a pump (typically as a proportion of its full pumping capacity) +brick:Pump_On_Off_Status,,brick:Pump,,,,brick:EnumerationKind-On_Off,brick:Status,, +brick:Pump_Status,,brick:Pump,,,,,brick:Status,,Status of a pump +brick:PV_Current_Output_Sensor,,,,,,,,(deprecated) (alias), +brick:Radiant_Panel_Temperature_Sensor,,brick:Radiant_Panel,,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of the radiant panel of the radiant heating and cooling HVAC system. +brick:Radiant_Panel_Temperature_Setpoint,,brick:Radiant_Panel,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of radiant panel. +brick:Radon_Concentration_Sensor,,,brick:Air,brick:Radon,,quantitykind:ActivityConcentration,brick:Sensor,,Measures the concentration of radioactivity due to radon +brick:Rain_Duration_Sensor,,,brick:Rain,,,quantitykind:Time,brick:Sensor,,Measures the duration of precipitation within some time frame +brick:Rain_Level_Sensor,,,brick:Rain,,,quantitykind:Depth,brick:Sensor,,Measures the amount of precipitation fallen +brick:Rated_Speed_Setpoint,,,,,,,,(deprecated),Sets rated speed +brick:Reactive_Energy_Sensor,,,,,,quantitykind:ReactiveEnergy,brick:Sensor,,Measures the integral of reactive power +brick:Reactive_Power_Sensor,,,,,,quantitykind:ReactivePower,brick:Sensor,,"Measures the portion of power that, averaged over a complete cycle of the AC waveform, is due to stored energy which returns to the source in each cycle" +brick:Refrigerant_Level_Sensor,,,brick:Refrigerant,,,quantitykind:LiquidLevel,brick:Sensor,, +brick:Reheat_Command,,brick:Reheat,,,,,brick:Command,,"A command to activate reheating, which is used for either heating or for dehumidification purposes" +brick:Relative_Humidity_Sensor,,,,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the present state of absolute humidity relative to a maximum humidity given the same temperature +brick:Relay_Command,,brick:Relay,,,,,brick:Command,,Commands to switch the relay +brick:Remotely_On_Off_Status,,,,,,,,(deprecated), +brick:Reset_Command,,,,,,,brick:Reset_Command,,"Commands that reset a flag, property or value to its default" +brick:Reset_Setpoint,,,,,,,brick:Reset_Setpoint,,Setpoints used in reset strategies +brick:Return_Air_CO_Sensor,,,brick:Return_Air,brick:CO,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO in return air +brick:Return_Air_CO2_Sensor,,,brick:Return_Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,Measures the concentration of CO2 in return air +brick:Return_Air_CO2_Setpoint,,,brick:Return_Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Setpoint,,Sets some property of CO2 in Return Air +brick:Return_Air_Dewpoint_Sensor,,,brick:Return_Air,,,quantitykind:DewPointTemperature,brick:Sensor,,Senses the dewpoint temperature of return air +brick:Return_Air_Differential_Pressure_Sensor,,,brick:Return_Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between the return and supply side +brick:Return_Air_Differential_Pressure_Setpoint,,,brick:Return_Air,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a return air duct or conduit +brick:Return_Air_Enthalpy_Sensor,,,brick:Return_Air,,,quantitykind:Enthalpy,brick:Sensor,,Measures the total heat content of return air +brick:Return_Air_Flow_Sensor,,,brick:Return_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of return air +brick:Return_Air_Grains_Sensor,,,brick:Return_Air,,,quantitykind:SpecificHumidity,brick:Sensor,,Measures the mass of water vapor in return air +brick:Return_Air_Humidity_Sensor,,,brick:Return_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of return air +brick:Return_Air_Humidity_Setpoint,,,brick:Return_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for return air +brick:Return_Air_Temperature_Alarm,,,brick:Return_Air,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of return air. +brick:Return_Air_Temperature_High_Reset_Setpoint,,,brick:Return_Air,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Return_Air_Temperature_Low_Reset_Setpoint,,,brick:Return_Air,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Return_Air_Temperature_Sensor,,,brick:Return_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of return air +brick:Return_Air_Temperature_Setpoint,,,brick:Return_Air,,,quantitykind:Temperature,brick:Setpoint,,"The target temperature for return air, often used as an approximation of zone air temperature" +brick:Room_Air_Temperature_Sensor,,,brick:Room_Air,,,quantitykind:Temperature,brick:Sensor,, +brick:Room_Air_Temperature_Setpoint,,,brick:Room_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of room air +brick:Run_Enable_Command,,brick:Run,,,,,brick:Enable_Command,, +brick:Run_Request_Status,,,,,,,,(deprecated),Indicates if a request has been filed to start a device or equipment +brick:Run_Status,,brick:Run,,,,,brick:Status,, +brick:Run_Time_Sensor,,brick:Run,,,,quantitykind:Time,brick:Sensor,(alias), +brick:Sash_Position_Sensor,,brick:Fume_Hood_Sash,,,,quantitykind:OpeningRatio,brick:Sensor,,Measures the current position of a sash in terms of the percent of fully open +brick:Schedule_Temperature_Setpoint,,,,,,,,(deprecated),The current setpoint as indicated by the schedule +brick:Sensor,,,,,,,brick:Sensor,,A Sensor is an input point that represents the value of a device or instrument designed to detect and measure a variable (ASHRAE Dictionary). +brick:Sensor_Failure_Alarm,,,,,,,brick:Sensor_Failure_Alarm,, +brick:Setpoint,,,,,,,brick:Setpoint,,A Setpoint is an input value at which the desired property is set +brick:Short_Cycle_Alarm,,,,,,,brick:Short_Cycle_Alarm,,An alarm that indicates a short cycle occurred. A short cycle occurs when a cooling cycle is prevented from completing its full cycle +brick:Smoke_Alarm,,,,,,,brick:Smoke_Alarm,,An alarm that indicates the off-normal conditions associated with smoke. +brick:Smoke_Detection_Alarm,,,,,,,brick:Smoke_Detection_Alarm,, +brick:Soil_Temperature_Sensor,,,brick:Soil,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of soil +brick:Solar_Azimuth_Angle_Sensor,,,brick:Solar,,,quantitykind:Azimuth,brick:Sensor,,Measures the azimuth angle of the sun +brick:Solar_Irradiance_Sensor,,,brick:Solar,,,quantitykind:Irradiance,brick:Sensor,,Measures solar irradiance levels for photovoltaic systems +brick:Solar_Zenith_Angle_Sensor,,,brick:Solar,,,quantitykind:Zenith,brick:Sensor,,Measures the zenith angle of the sun +brick:Speed_Command,,,,,,quantitykind:Speed,brick:Command,,A command to set speed to a certain degree. +brick:Speed_Mode_Status,,,,,,brick:EnumerationKind-Speed_Mode,brick:Status,,"Indicates the speed mode of a motor with various categorical settings, such as a multi-state value including low, medium, and high." +brick:Speed_Reset_Command,,,,,,quantitykind:Speed,brick:Reset_Command,, +brick:Speed_Sensor,,,,,,quantitykind:Speed,brick:Sensor,,Measures the magnitude of velocity of some form of movement +brick:Speed_Setpoint,,,,,,quantitykind:Speed,brick:Setpoint,,Sets speed +brick:Speed_Setpoint_Limit,,,,,,quantitykind:Speed,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Speed_Setpoint. +brick:Stage_Enable_Command,,,,,,brick:EnumerationKind-Stage,brick:Command,,A point representing a discrete stage which the equipment should be operating at. The desired stage number should be identified by an entity property +brick:Stages_Status,,,,,,brick:EnumerationKind-Stage,brick:Status,,Indicates which stage a control loop or equipment is in +brick:Standby_Cooling_Zone_Air_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Standby_Glycool_Unit_On_Off_Status,,,,,,,,(deprecated),Indicates the on/off status of a standby glycool unit +brick:Standby_Heating_Zone_Air_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Standby_Load_Shed_Command,,,,,,,,(deprecated), +brick:Standby_Target_Zone_Air_Temperature_Setpoint,,,,,,,,(deprecated), +brick:Standby_Unit_On_Off_Status,,,,,,,,(deprecated),Indicates the on/off status of a standby unit +brick:Start_Stop_Command,,,,,,brick:EnumerationKind-Start_Stop,brick:Command,,A Start/Stop Command controls or reports the active/inactive status of a control sequence +brick:Start_Stop_Counter,,,,,,,,(deprecated) (alias), +brick:Start_Stop_Status,,,,,,brick:EnumerationKind-Start_Stop,brick:Status,,Indicates the active/inactive status of a control loop (but not equipment activities or relays -- use On/Off for this purpose) +brick:Static_Pressure_Deadband_Setpoint,,,,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure +brick:Static_Pressure_Integral_Time_Parameter,,,,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Static_Pressure_Proportional_Band_Parameter,,,,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Static_Pressure_Sensor,,,,,,quantitykind:StaticPressure,brick:Sensor,,Measures resistance to airflow in a heating and cooling system's components and duct work +brick:Static_Pressure_Setpoint,,,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure +brick:Static_Pressure_Setpoint_Limit,,,,,,quantitykind:StaticPressure,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Static_Pressure_Setpoint. +brick:Static_Pressure_Step_Parameter,,,,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Status,,,,,,,brick:Status,,"A Status is input point that reports the current operating mode, state, position, or condition of an item. Statuses are observations and should be considered 'read-only'" +brick:Steam_On_Off_Command,,,brick:Steam,,,brick:EnumerationKind-On_Off,brick:Command,, +brick:Steam_Usage_Sensor,,,brick:Steam,,,,brick:Usage_Sensor,,"Measures the amount of steam that is consumed or used, over some period of time" +brick:Step_Parameter,,,,,,,brick:Step_Parameter,, +brick:Supply_Air_Dewpoint_Sensor,,,brick:Supply_Air,,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of supply air +brick:Supply_Air_Differential_Pressure_Sensor,,,brick:Supply_Air,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in pressure between an upstream and downstream of an air duct or other air conduit used to supply air into the building +brick:Supply_Air_Differential_Pressure_Setpoint,,,brick:Supply_Air,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target air differential pressure between an upstream and downstream point in a supply air duct or conduit +brick:Supply_Air_Duct_Pressure_Status,,,,,,,,(deprecated),Indicates if air pressure in supply duct is within expected bounds +brick:Supply_Air_Flow_Demand_Setpoint,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Demand_Setpoint,,Sets the rate of supply air flow required for a process +brick:Supply_Air_Flow_High_Reset_Setpoint,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:High_Reset_Setpoint,, +brick:Supply_Air_Flow_Low_Reset_Setpoint,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Flow_Reset_Setpoint,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Reset_Setpoint,,Setpoints used in Reset strategies +brick:Supply_Air_Flow_Sensor,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of supply air +brick:Supply_Air_Flow_Setpoint,,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow rate +brick:Supply_Air_Humidity_Sensor,,,brick:Supply_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of supply air +brick:Supply_Air_Humidity_Setpoint,,,brick:Supply_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for supply air +brick:Supply_Air_Integral_Gain_Parameter,,,brick:Supply_Air,,,,brick:Integral_Gain_Parameter,, +brick:Supply_Air_Proportional_Gain_Parameter,,,brick:Supply_Air,,,,brick:Proportional_Gain_Parameter,, +brick:Supply_Air_Smoke_Detection_Alarm,,,brick:Supply_Air,,,,brick:Smoke_Detection_Alarm,, +brick:Supply_Air_Static_Pressure_Deadband_Setpoint,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Deadband_Setpoint,,Sets the size of a deadband of static pressure of supply air +brick:Supply_Air_Static_Pressure_Integral_Time_Parameter,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Integral_Time_Parameter,, +brick:Supply_Air_Static_Pressure_Proportional_Band_Parameter,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Static_Pressure_Sensor,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Sensor,,The static pressure of air within supply regions of an HVAC system +brick:Supply_Air_Static_Pressure_Setpoint,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Setpoint,,Sets static pressure of supply air +brick:Supply_Air_Static_Pressure_Step_Parameter,,,brick:Supply_Air,,,quantitykind:StaticPressure,brick:Step_Parameter,, +brick:Supply_Air_Temperature_Alarm,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with the temperature of supply air. +brick:Supply_Air_Temperature_Cooling_Setpoint,,brick:Cooling,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of supply air for cooling +brick:Supply_Air_Temperature_Deadband_Setpoint,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature of supply air +brick:Supply_Air_Temperature_Heating_Setpoint,,brick:Heating,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of supply air for heating +brick:Supply_Air_Temperature_High_Reset_Setpoint,,,brick:Supply_Air,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Supply_Air_Temperature_Low_Reset_Setpoint,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Supply_Air_Temperature_Proportional_Band_Parameter,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Proportional_Band_Parameter,, +brick:Supply_Air_Temperature_Reset_Differential_Setpoint,,,brick:Supply_Air,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Supply_Air_Temperature_Sensor,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of supply air +brick:Supply_Air_Temperature_Setpoint,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint,,Temperature setpoint for supply air +brick:Supply_Air_Temperature_Setpoint_Limit,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint_Limit,,A parameter that places a lower or upper bound on the range of permitted values of a Supply_Air_Temperature_Setpoint. +brick:Supply_Air_Temperature_Step_Parameter,,,brick:Supply_Air,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Supply_Air_Velocity_Pressure_Sensor,,,brick:Supply_Air,,,quantitykind:DynamicPressure,brick:Sensor,, +brick:Switch_Status,,brick:Switch,,,,,brick:Status,,Status of a switch +brick:System_Enable_Command,,brick:System,,,,,brick:Enable_Command,,Enables operation of a system +brick:System_Shutdown_Status,,brick:System,,,,brick:EnumerationKind-Shutdown,brick:Status,,Indicates if a system has been shutdown +brick:System_Status,,brick:System,,,,,brick:Status,,Indicates properties of the activity of a system +brick:Target_Zone_Air_Temperature_Setpoint,,,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Temperature_Adjust_Sensor,,,,,,,,(deprecated),Measures user-provided adjustment of temperature +brick:Temperature_Alarm,,,,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature. +brick:Temperature_Alarm_Sensitivity_Parameter,,,,,,quantitykind:Temperature,brick:Alarm_Sensitivity_Parameter,,A parameter indicates the sensitivity to activate a temperature alarm. +brick:Temperature_Deadband_Setpoint,,,,,,quantitykind:Temperature,brick:Deadband_Setpoint,,Sets the size of a deadband of temperature +brick:Temperature_Differential_Reset_Setpoint,,,,,brick:Differential,quantitykind:Temperature,brick:Reset_Setpoint,, +brick:Temperature_High_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:High_Reset_Setpoint,, +brick:Temperature_Low_Reset_Setpoint,,,,,,quantitykind:Temperature,brick:Low_Reset_Setpoint,, +brick:Temperature_Parameter,,,,,,quantitykind:Temperature,brick:Parameter,,Parameters relevant to temperature-related systems and points +brick:Temperature_Sensor,,,,,,quantitykind:Temperature,brick:Sensor,,Measures temperature: the physical property of matter that quantitatively expresses the common notions of hot and cold +brick:Temperature_Setpoint,,,,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature +brick:Temperature_Step_Parameter,,,,,,quantitykind:Temperature,brick:Step_Parameter,, +brick:Temperature_Tolerance_Parameter,,,,,,quantitykind:Temperature,brick:Tolerance_Parameter,,A parameter determining the difference between upper and lower limits of temperature. +brick:Temporary_Occupancy_Status,,,,,,,,(deprecated),"For systems that differentiate between scheduled occupied/unoccupied mode, this indicates if a space is temporarily occupied when it would otherwise be unoccupied" +brick:Thermal_Energy_Usage_Sensor,,,,,,quantitykind:ThermalEnergy,brick:Usage_Sensor,,A sensor that records the quantity of thermal energy consumed in a given period +brick:Thermal_Power_Sensor,,,,,,quantitykind:ThermalPower,brick:Sensor,, +brick:Thermostat_Status,,brick:Thermostat,,,,,brick:Status,,Status of a thermostat +brick:Time_Parameter,,,,,,,brick:Time_Parameter,, +brick:Time_Setpoint,,,,,,quantitykind:Time,brick:Setpoint,, +brick:Tint_Command,,,,,,,brick:Command,Tint,The target level of window tint. +brick:Tint_Status,,,,,,,brick:Status,Tint,"The current level of window tint, errors, or transient states." +brick:Tolerance_Parameter,,,,,,,brick:Tolerance_Parameter,,difference between upper and lower limits of size for a given nominal dimension or value. +brick:Torque_Sensor,,,,,,quantitykind:Torque,brick:Sensor,,"Measures torque, the tendency of a force to rotate an object about some axis" +brick:TVOC_Level_Sensor,,,brick:Air,brick:TVOC,,quantitykind:MassDensity,brick:Sensor,,A sensor measuring the level of all VOCs in air +brick:TVOC_Sensor,,,brick:Air,brick:TVOC,,quantitykind:MassDensity,brick:Sensor,, +brick:Underfloor_Air_Plenum_Static_Pressure_Sensor,,brick:Underfloor_Air_Plenum,,,,quantitykind:StaticPressure,brick:Sensor,,Measures the outward push of air against the plenum surfaces and used to measure the resistance when air moves through the plenum +brick:Underfloor_Air_Plenum_Static_Pressure_Setpoint,,brick:Underfloor_Air_Plenum,,,,quantitykind:StaticPressure,brick:Setpoint,,Sets the underfloor air plenum static pressure +brick:Underfloor_Air_Temperature_Sensor,,,brick:Air,,,quantitykind:Temperature,brick:Sensor,Underfloor,Measures the temperature of underfloor air +brick:Unit_Failure_Alarm,,,,,,,brick:Unit_Failure_Alarm,,An alarm that indicates the failure of an equipment or device +brick:Unoccupied_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied +brick:Unoccupied_Cooling_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Unoccupied_Cooling_Mode_Status,brick:Unoccupied,brick:Cooling,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied cooling mode" +brick:Unoccupied_Cooling_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Cooling,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets supply air flow for cooling when unoccupied +brick:Unoccupied_Cooling_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Cooling,,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Cooling_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Cooling_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Cooling,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for cooling within a specific zone +brick:Unoccupied_Discharge_Air_Flow_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Unoccupied_Discharge_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Discharge_Air,,,quantitykind:Temperature,brick:Setpoint,(alias), +brick:Unoccupied_Heating_Discharge_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Discharge_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,(alias), +brick:Unoccupied_Heating_Mode_Status,brick:Unoccupied,brick:Heating,,,,brick:EnumerationKind-Mode,brick:Status,,"Indicates whether a system, device or control loop is in an unoccupied heating mode" +brick:Unoccupied_Heating_Supply_Air_Flow_Setpoint,brick:Unoccupied,brick:Heating,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Heating_Temperature_Deadband_Setpoint,brick:Unoccupied,brick:Heating,,,,quantitykind:Temperature,brick:Deadband_Setpoint,, +brick:Unoccupied_Heating_Temperature_Setpoint,brick:Unoccupied,brick:Heating,,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Heating_Zone_Air_Temperature_Setpoint,brick:Unoccupied,brick:Heating,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of air when unoccupied for heating within a specific zone +brick:Unoccupied_Humidity_Setpoint,brick:Unoccupied,,brick:Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Target humidity level when the location is unoccupied. +brick:Unoccupied_Load_Shed_Command,brick:Unoccupied,,,,,,brick:Load_Shed_Command,, +brick:Unoccupied_Mode_Status,brick:Unoccupied,,,,,brick:EnumerationKind-Mode,brick:Status,, +brick:Unoccupied_Return_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Return_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Room_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Room_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Flow_Setpoint,brick:Unoccupied,,brick:Supply_Air,,,quantitykind:VolumeFlowRate,brick:Setpoint,, +brick:Unoccupied_Supply_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Supply_Air,,,quantitykind:Temperature,brick:Setpoint,, +brick:Unoccupied_Target_Zone_Air_Temperature_Setpoint,brick:Unoccupied,,brick:Zone_Air,,,quantitykind:Temperature,brick:Setpoint,,Target Setpoint (also known as Common Setpoint) is a reference point representing the desired unoccupied air temperature in a specific zone of a building. This setpoint acts as a baseline from which deadband setpoints are established by adding or subtracting a deadband width. +brick:Usage_Sensor,,,,,,,brick:Usage_Sensor,,"Measures the amount of some substance that is consumed or used, over some period of time" +brick:Valve_Command,,brick:Valve,,,,,brick:Command,,Controls or reports the openness of a valve (typically as a proportion of its full range of motion) +brick:Valve_Position_Alarm,,brick:Valve,,,,quantitykind:OpeningRatio,brick:Alarm,,An alarm that indicates that the valve position is not in a normal state. +brick:Valve_Position_Command,,brick:Valve,,,,quantitykind:OpeningRatio,brick:Command,,Controls the position (the degree of openness) of a valve +brick:Valve_Position_Sensor,,brick:Valve,,,,quantitykind:OpeningRatio,brick:Sensor,,Measures the current position of a valve in terms of the percent of fully open +brick:Valve_Status,,brick:Valve,,,,,brick:Status,,The current status of the valve. +brick:Velocity_Pressure_Sensor,,,,,,quantitykind:DynamicPressure,brick:Sensor,,Measures the difference between total pressure and static pressure +brick:Velocity_Pressure_Setpoint,,,,,,quantitykind:DynamicPressure,brick:Setpoint,,Sets static veloicty pressure +brick:Vent_Operating_Mode_Status,,,,,,,,(deprecated),Indicates the current operating mode of a vent +brick:Ventilation_Air_Flow_Ratio_Limit,,,,,,,,(deprecated),A parameter that places a lower or upper bound on the range of permitted values of a Ventilation_Air_Flow_Ratio_Setpoint. +brick:VFD_Enable_Command,,brick:VFD,,,,,brick:Enable_Command,,Enables operation of a variable frequency drive +brick:Voltage_Alarm,,,,,,quantitykind:Voltage,brick:Alarm,,An alarm that indicates the voltage is not in a normal state. +brick:Voltage_Imbalance_Sensor,,,,,,quantitykind:VoltageImbalance,brick:Sensor,,A sensor which measures the voltage difference (imbalance) between phases of an electrical system +brick:Voltage_Ratio_Setpoint,,,,,,quantitykind:VoltageRatio,brick:Setpoint,,Sets the ratio of voltage in a transformer +brick:Voltage_Sensor,,,,,,quantitykind:Voltage,brick:Sensor,,Measures the voltage of an electrical device or object +brick:Warm_Cool_Adjust_Sensor,,,,,,,,(deprecated),"User provided adjustment of zone temperature, typically in the range of +/- 5 degrees" +brick:Warmest_Zone_Air_Temperature_Sensor,,,,,,,,(deprecated),The zone temperature that is warmest; drives the supply temperature of cold air. A computed value rather than a physical sensor. Also referred to as a 'Highest Zone Air Temperature Sensor' +brick:Waste_Amount_Sensor,,,,,,,,(deprecated),A metric used for measuring the quantity of waste generated in a building. +brick:Water_Alarm,,,brick:Water,,,,brick:Leak_Alarm,,"Alarm that indicates an undesirable event with a pipe, container, or equipment carrying water e.g. water leak" +brick:Water_Differential_Pressure_Sensor,,,brick:Water,,brick:Differential,quantitykind:Pressure,brick:Sensor,,Measures the difference in water pressure between two points in a system. +brick:Water_Differential_Pressure_Setpoint,,,brick:Water,,brick:Differential,quantitykind:Pressure,brick:Setpoint,,Sets the target water differential pressure between an upstream and downstream point in a water pipe or conduit +brick:Water_Differential_Temperature_Sensor,,,brick:Water,,brick:Differential,quantitykind:Temperature,brick:Sensor,,Measures the difference in water temperature between an upstream and downstream point in a pipe or conduit +brick:Water_Differential_Temperature_Setpoint,,,brick:Water,,brick:Differential,quantitykind:Temperature,brick:Setpoint,,Sets the target differential temperature between the start and end of a heat transfer cycle in a water circuit +brick:Water_Flow_Sensor,,,brick:Water,,,quantitykind:VolumeFlowRate,brick:Sensor,,Measures the rate of flow of water +brick:Water_Flow_Setpoint,,,brick:Water,,,quantitykind:VolumeFlowRate,brick:Setpoint,,Sets the target flow rate of water +brick:Water_Level_Alarm,,,brick:Water,,,quantitykind:LiquidLevel,brick:Alarm,,An alarm that indicates a high or low water level e.g. in a basin +brick:Water_Level_Sensor,,,brick:Water,,,quantitykind:LiquidLevel,brick:Sensor,,Measures the height/level of water in some container +brick:Water_Loss_Alarm,,,brick:Water,,,,brick:Leak_Alarm,,An alarm that indicates a loss of water e.g. during transport +brick:Water_Pressure_Sensor,,,brick:Water,,,quantitykind:Pressure,brick:Sensor,,Measures the pressure exerted by water in a system. +brick:Water_Pressure_Setpoint,,,brick:Water,,,quantitykind:Pressure,brick:Setpoint,, +brick:Water_Temperature_Alarm,,,brick:Water,,,quantitykind:Temperature,brick:Alarm,,An alarm that indicates the off-normal conditions associated with temperature of water. +brick:Water_Temperature_Sensor,,,brick:Water,,,quantitykind:Temperature,brick:Sensor,,Measures the temperature of water +brick:Water_Temperature_Setpoint,,,brick:Water,,,quantitykind:Temperature,brick:Setpoint,,Sets temperature of water +brick:Water_Usage_Sensor,,,brick:Water,,,,brick:Usage_Sensor,,"Measures the amount of water that is consumed, over some period of time" +brick:Wind_Direction_Sensor,,,brick:Wind,,,quantitykind:Azimuth,brick:Sensor,,Measures the direction of wind in degrees relative to North +brick:Wind_Speed_Sensor,,,brick:Wind,,,quantitykind:Speed,brick:Sensor,,"Measured speed of wind, caused by air moving from high to low pressure" +brick:Zone_Air_Conditioning_Mode_Status,,,,,,brick:EnumerationKind-Air_Conditioning_Mode,brick:Status,,Indicates the mode of AC for a zone +brick:Zone_Air_Dewpoint_Sensor,,,brick:Zone_Air,,,quantitykind:DewPointTemperature,brick:Sensor,,Measures dewpoint of zone air +brick:Zone_Air_Humidity_Sensor,,,brick:Zone_Air,,,quantitykind:RelativeHumidity,brick:Sensor,,Measures the relative humidity of zone air +brick:Zone_Air_Humidity_Setpoint,,,brick:Zone_Air,,,quantitykind:RelativeHumidity,brick:Setpoint,,Humidity setpoint for zone air +brick:Zone_Air_Temperature_Sensor,,,brick:Zone_Air,,,quantitykind:Temperature,brick:Sensor,,A physical or virtual sensor which represents the temperature of an HVAC Zone +brick:Zone_CO2_Level_Sensor,,,brick:Zone_Air,brick:CO2,,quantitykind:AmountOfSubstanceFraction,brick:Sensor,,A physical or virtual sensor which represents the CO2 level of an HVAC Zone +brick:Zone_Occupied_Load_Shed_Command,,,,,,,,(deprecated), +brick:Zone_Standby_Load_Shed_Command,,,,,,,,(deprecated), +brick:Zone_Unoccupied_Load_Shed_Command,,,,,,,,(deprecated), diff --git a/bricksrc/substances.csv b/bricksrc/substances.csv new file mode 100644 index 00000000..35e31b6f --- /dev/null +++ b/bricksrc/substances.csv @@ -0,0 +1,70 @@ +@id,brick:atConnectionPoint,brick:hasQualification,brick:inLoop/inConnection/inLocation,skos:broader,todo:,skos:definition +brick:Air,,,,brick:Air,,"the invisible gaseous substance surrounding the earth, a mixture mainly of oxygen and nitrogen." +brick:Ammonia,,,,brick:Ammonia,,Ammonia +brick:Blowdown_Water,,,,brick:Water,Blowdown,Water expelled from a system to remove mineral build up +brick:Building_Air,,,brick:Building,brick:Air,,air contained within a building +brick:Bypass_Air,,,,brick:Air,Bypass,"air in a bypass duct, used to relieve static pressure" +brick:Bypass_Water,,,,brick:Water,Bypass,Water that circumvents a piece of equipment or system +brick:Chilled_Water,,,brick:Chilled_Water_Loop,brick:Water,,water used as a cooling medium (particularly in air-conditioning systems or in processes) at below ambient temperature. +brick:CO,,,,brick:CO,,Carbon Monoxide in the vapor phase +brick:CO2,,,,brick:CO2,,Carbon Dioxide in the vapor phase +brick:Collection_Basin_Water,,,brick:Collection_Basin,brick:Water,,"Water transiently collected and directed to the sump or pump suction line, typically integral with a cooling tower" +brick:Condenser_Water,,,brick:Condenser_Water_Loop,brick:Water,,Water used used to remove heat through condensation +brick:Deionized_Water,,brick:Deionized,,brick:Water,,Water which has been purified by removing its ions (constituting the majority of non-particulate contaminants) +brick:Discharge_Air,,,brick:Discharge_Air_Duct,brick:Air,,the air exiting the registers (vents). +brick:Domestic_Hot_Water,,,brick:Domestic_Hot_Water_Loop,brick:Water,, +brick:Domestic_Water,,,brick:Domestic_Water_Loop,brick:Water,,A collection of equipment that transport and regulate domestic water among each other +brick:Entering_Chilled_Water,brick:Entering,,brick:Chilled_Water_Loop,brick:Water,,Chilled water that is entering a piece of equipment or system +brick:Entering_Condenser_Water,brick:Entering,,brick:Condenser_Water_Loop,brick:Water,,"In a condenser water loop, this is water being brought away from the condenser side of a heat-rejection device (e.g. chiller). It is the 'warm' side." +brick:Entering_Domestic_Hot_Water,brick:Entering,,brick:Domestic_Hot_Water_Loop,brick:Water,,Domestic hot water that is entering a piece of equipment or system +brick:Entering_High_Temperature_Hot_Water,brick:Entering,brick:High_Temperature,brick:Hot_Water_Loop,brick:Water,,High-temperature hot water entering a hot water system +brick:Entering_Hot_Water,brick:Entering,,brick:Hot_Water_Loop,brick:Water,, +brick:Entering_Medium_Temperature_Hot_Water,brick:Entering,brick:Medium_Temperature,brick:Hot_Water_Loop,brick:Water,,Medium-temperature hot water entering a hot water system +brick:Entering_Water,brick:Entering,,,brick:Water,,Water that is entering a piece of equipment or system +brick:Exhaust_Air,,,brick:Exhaust_Air_Duct,brick:Air,,"air that must be removed from a space due to contaminants, regardless of pressurization" +brick:Fluid,,,,brick:Fluid,,"substance, as a liquid or gas, that is capable of flowing and that changes shape when acted on by a force." +brick:Formaldehyde,,,,brick:Formaldehyde,,Formaldehyde +brick:Frost,,,,brick:Frost,,"frost formed on the cold surface (tubes, plates) of a cooling coil." +brick:Fuel_Oil,,,,brick:Fuel_Oil,,Petroleum based oil burned for energy +brick:Gas,,,,brick:Gas,,"state of matter in which substances exist in the form of nonaggregated molecules and which, within acceptable limits of accuracy, satisfy the ideal gas laws; usually a highly superheated vapor. See [[state]]." +brick:Gasoline,,,,brick:Gasoline,,Petroleum derived liquid used as a fuel source +brick:Glycol,,,,brick:Glycol,, +brick:Hail,,,,brick:Hail,,pellets of frozen rain which fall in showers from cumulonimbus clouds. +brick:High_Temperature_Hot_Water,,brick:High_Temperature,brick:Hot_Water_Loop,brick:Water,,High-temperature hot water +brick:Hot_Water,,,brick:Hot_Water_Loop,brick:Water,,Hot water used for HVAC heating or supply to hot taps +brick:Ice,,,,brick:Ice,,Water in its solid form +brick:Leaving_Chilled_Water,brick:Leaving,,brick:Chilled_Water_Loop,brick:Water,,Chilled water that is leaving a piece of equipment or system +brick:Leaving_Condenser_Water,brick:Leaving,,brick:Condenser_Water_Loop,brick:Water,,"In a condenser water loop, this is water being brought to the condenser side of a heat-rejection device (e.g. chiller). It is the 'cold' side." +brick:Leaving_Domestic_Hot_Water,brick:Leaving,,brick:Domestic_Hot_Water_Loop,brick:Water,,Domestic hot water that is leaving a piece of equipment or system +brick:Leaving_High_Temperature_Hot_Water,brick:Leaving,brick:High_Temperature,brick:Hot_Water_Loop,brick:Water,,High-temperature hot water leaving a hot water system +brick:Leaving_Hot_Water,brick:Leaving,,brick:Hot_Water_Loop,brick:Water,, +brick:Leaving_Medium_Temperature_Hot_Water,brick:Leaving,brick:Medium_Temperature,brick:Hot_Water_Loop,brick:Water,,Medium-temperature hot water leaving a hot water system +brick:Leaving_Water,brick:Leaving,,,brick:Water,,Water that is leaving a piece of equipment or system +brick:Light,,,,brick:Light,, +brick:Liquid,,,,brick:Liquid,,"state of matter intermediate between crystalline substances and gases in which the volume of a substance, but not the shape, remains relatively constant." +brick:Liquid_CO2,,,,brick:Liquid_CO2,,Carbon Dioxide in the liquid phase +brick:Makeup_Water,,,,brick:Water,Makeup,"Water used used to makeup water loss through leaks, evaporation, or blowdown" +brick:Medium_Temperature_Hot_Water,,brick:Medium_Temperature,brick:Hot_Water_Loop,brick:Water,,Medium-temperature hot water +brick:Methane,,,,brick:Methane,,Methane +brick:Mixed_Air,,,brick:Mixed_Air_Duct,brick:Air,,(1) air that contains two or more streams of air. (2) combined outdoor air and recirculated air. +brick:Natural_Gas,,,,brick:Natural_Gas,,Fossil fuel energy source consisting largely of methane and other hydrocarbons +brick:NO2,,,,brick:NO2,,Nitrogen Dioxide +brick:Oil,,,,brick:Oil,,"a viscous liquid derived from petroleum, especially for use as a fuel or lubricant." +brick:Outside_Air,,,brick:Outside,brick:Air,,"air external to a defined zone (e.g., corridors)." +brick:Ozone,,,,brick:Ozone,,Ozone +brick:Particulate_Matter,,,,brick:Particulate_Matter,,a mixture of solid particles and liquid droplets found in the air +brick:PM1,,,,brick:PM1,,Particulate matter with a diameter of 1 micrometer and smaller +brick:PM2.5,,,,brick:PM2.5,,Particulate matter with a diameter of 2.5 micrometers and smaller +brick:PM10,,,,brick:PM10,,Particulate matter with a diameter of 10 micrometers and smaller +brick:Potable_Water,,brick:Potable,,brick:Water,,Water that is safe to drink +brick:Radon,,,,brick:Radon,,Radon +brick:Refrigerant,,,,brick:Refrigerant,,A refrigerant is a working fluid used in the refrigeration cycle of air conditioning systems and heat pumps where in most cases they undergo a repeated phase transition from a liquid to a gas and back again. +brick:Return_Air,,,brick:Return_Air_Duct,brick:Air,,"air removed from a space to be recirculated or exhausted. Air extracted from a space and totally or partially returned to an air conditioner, furnace, or other heating, cooling, or ventilating system." +brick:Room_Air,,,brick:Room,brick:Air,, +brick:Soil,,,,brick:Soil,, +brick:Solid,,,,brick:Solid,,"one of the three states or phases of matter characterized by stability of dimensions, relative incompressibility, and molecular motion held to limited oscillation." +brick:Steam,,,,brick:Steam,,water in the vapor phase. +brick:Supply_Air,,,brick:Supply_Air_Duct,brick:Air,,"(1) air delivered by mechanical or natural ventilation to a space, composed of any combination of outdoor air, recirculated air, or transfer air. (2) air entering a space from an air-conditioning, heating, or ventilating apparatus for the purpose of comfort conditioning. Supply air is generally filtered, fan forced, and either heated, cooled, humidified, or dehumidified as necessary to maintain specified conditions. Only the quantity of outdoor air within the supply airflow may be used as replacement air." +brick:TVOC,,,,brick:TVOC,,Total Volatile Organic Compounds +brick:Water,,,,brick:Water,,"transparent, odorless, tasteless liquid; a compound of hydrogen and oxygen (H2O), containing 11.188% hydrogen and 88.812% oxygen by mass; freezing at 32°F (0°C); boiling near 212°F (100°C)." +brick:Zone_Air,,,brick:Zone,brick:Air,,"air inside a defined zone (e.g., corridors)."